Neural Probes for Chronic Applications

Cited 33 time in webofscience Cited 0 time in scopus
  • Hit : 548
  • Download : 429
DC FieldValueLanguage
dc.contributor.authorKook, Geonko
dc.contributor.authorLee, Sungwooko
dc.contributor.authorLee, Heechulko
dc.contributor.authorCho, Il-Jooko
dc.contributor.authorLee, Hyunjoo Jennyko
dc.date.accessioned2016-12-01T08:08:31Z-
dc.date.available2016-12-01T08:08:31Z-
dc.date.created2016-11-15-
dc.date.created2016-11-15-
dc.date.created2016-11-15-
dc.date.issued2016-10-
dc.identifier.citationMICROMACHINES, v.7, no.10-
dc.identifier.issn2072-666X-
dc.identifier.urihttp://hdl.handle.net/10203/214653-
dc.description.abstractDeveloped over approximately half a century, neural probe technology is now a mature technology in terms of its fabrication technology and serves as a practical alternative to the traditional microwires for extracellular recording. Through extensive exploration of fabrication methods, structural shapes, materials, and stimulation functionalities, neural probes are now denser, more functional and reliable. Thus, applications of neural probes are not limited to extracellular recording, brain-machine interface, and deep brain stimulation, but also include a wide range of new applications such as brain mapping, restoration of neuronal functions, and investigation of brain disorders. However, the biggest limitation of the current neural probe technology is chronic reliability; neural probes that record with high fidelity in acute settings often fail to function reliably in chronic settings. While chronic viability is imperative for both clinical uses and animal experiments, achieving one is a major technological challenge due to the chronic foreign body response to the implant. Thus, this review aims to outline the factors that potentially affect chronic recording in chronological order of implantation, summarize the methods proposed to minimize each factor, and provide a performance comparison of the neural probes developed for chronic applications.-
dc.languageEnglish-
dc.publisherMDPI AG-
dc.subjectSILICON MICROELECTRODE ARRAYS-
dc.subjectEMBEDDED MICROFLUIDIC CHANNELS-
dc.subjectINTRACORTICAL ELECTRODE ARRAY-
dc.subjectCHRONIC RECORDING FUNCTION-
dc.subjectBRAIN-BARRIER STABILITY-
dc.subjectIN-VIVO EVALUATION-
dc.subjectTISSUE-RESPONSE-
dc.subjectCEREBRAL-CORTEX-
dc.subjectDRUG-DELIVERY-
dc.subjectPENETRATING ELECTRODES-
dc.titleNeural Probes for Chronic Applications-
dc.typeArticle-
dc.identifier.wosid000389131300009-
dc.identifier.scopusid2-s2.0-84994893917-
dc.type.rimsART-
dc.citation.volume7-
dc.citation.issue10-
dc.citation.publicationnameMICROMACHINES-
dc.identifier.doi10.3390/mi7100179-
dc.contributor.localauthorLee, Hyunjoo Jenny-
dc.contributor.nonIdAuthorKook, Geon-
dc.contributor.nonIdAuthorLee, Heechul-
dc.contributor.nonIdAuthorCho, Il-Joo-
dc.description.isOpenAccessY-
dc.type.journalArticleReview-
dc.subject.keywordAuthorbiocompatibility-
dc.subject.keywordAuthorbiocompatible coating-
dc.subject.keywordAuthorchronic implant-
dc.subject.keywordAuthorforeign body response-
dc.subject.keywordAuthorneural probe-
dc.subject.keywordAuthorneural recording-
dc.subject.keywordPlusSILICON MICROELECTRODE ARRAYS-
dc.subject.keywordPlusEMBEDDED MICROFLUIDIC CHANNELS-
dc.subject.keywordPlusINTRACORTICAL ELECTRODE ARRAY-
dc.subject.keywordPlusCHRONIC RECORDING FUNCTION-
dc.subject.keywordPlusBRAIN-BARRIER STABILITY-
dc.subject.keywordPlusIN-VIVO EVALUATION-
dc.subject.keywordPlusTISSUE-RESPONSE-
dc.subject.keywordPlusCEREBRAL-CORTEX-
dc.subject.keywordPlusDRUG-DELIVERY-
dc.subject.keywordPlusPENETRATING ELECTRODES-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
97752.pdf(8.07 MB)Download
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 33 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0