dc.description.abstract | Intravascular optical coherence tomography (IV-OCT) is a high-resolution imaging method used to visualize the internal structures of walls of coronary arteries in vivo. However, accurate characterization of atherosclerotic plaques with gray-scale IV-OCT images is often limited by various intrinsic artifacts. In this study, we present an algorithm for characterizing lipid-rich plaques with a spectroscopic OCT technique based on a Gaussian center of mass (GCOM) metric. The GCOM metric, which reflects the absorbance properties of lipids, was validated using a lipid phantom. In addition, the proposed characterization method was successfully demonstrated in vivo using an atherosclerotic rabbit model and was found to have a sensitivity and specificity of 94.3% and 76.7% for lipid classification, respectively. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE | - |
dc.language | English | - |
dc.publisher | SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS | - |
dc.title | Characterization of lipid-rich plaques using spectroscopic optical coherence tomography | - |
dc.type | Article | - |
dc.identifier.wosid | 000381917800025 | - |
dc.identifier.scopusid | 2-s2.0-84978971676 | - |
dc.type.rims | ART | - |
dc.citation.volume | 21 | - |
dc.citation.issue | 7 | - |
dc.citation.publicationname | JOURNAL OF BIOMEDICAL OPTICS | - |
dc.identifier.doi | 10.1117/1.JBO.21.7.075004 | - |
dc.contributor.localauthor | Oh, Wang-Yuhl | - |
dc.contributor.localauthor | Yoo, Hongki | - |
dc.contributor.nonIdAuthor | Nam, Hyeong Soo | - |
dc.contributor.nonIdAuthor | Song, Joon Woo | - |
dc.contributor.nonIdAuthor | Lee, Jae Joong | - |
dc.contributor.nonIdAuthor | Kim, Jin Won | - |
dc.description.isOpenAccess | N | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | optical coherence tomography | - |
dc.subject.keywordAuthor | lipid-rich plaque | - |
dc.subject.keywordAuthor | spectroscopic optical coherence tomography | - |
dc.subject.keywordAuthor | tissue characterization | - |
dc.subject.keywordPlus | NEAR-INFRARED SPECTROSCOPY | - |
dc.subject.keywordPlus | BLOOD-OXYGEN SATURATION | - |
dc.subject.keywordPlus | IN-VIVO | - |
dc.subject.keywordPlus | ATHEROSCLEROTIC PLAQUES | - |
dc.subject.keywordPlus | SCATTERING | - |
dc.subject.keywordPlus | ABSORPTION | - |
dc.subject.keywordPlus | DERMATOLOGY | - |
dc.subject.keywordPlus | MECHANISMS | - |
dc.subject.keywordPlus | MICROSCOPY | - |
dc.subject.keywordPlus | DISEASE | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.