DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Hyun Jin | ko |
dc.contributor.author | Kim, Hyun Nam | ko |
dc.contributor.author | Raza, Hamid Saeed | ko |
dc.contributor.author | Park, Han Beom | ko |
dc.contributor.author | Cho, Sung-Oh | ko |
dc.date.accessioned | 2016-07-25T09:37:46Z | - |
dc.date.available | 2016-07-25T09:37:46Z | - |
dc.date.created | 2016-07-12 | - |
dc.date.created | 2016-07-12 | - |
dc.date.issued | 2016-06 | - |
dc.identifier.citation | NUCLEAR ENGINEERING AND TECHNOLOGY, v.48, no.3, pp.799 - 804 | - |
dc.identifier.issn | 1738-5733 | - |
dc.identifier.uri | http://hdl.handle.net/10203/212129 | - |
dc.description.abstract | A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube. Copyright (C) 2016, Published by Elsevier Korea LLC on behalf of Korean Nuclear Society | - |
dc.language | English | - |
dc.publisher | KOREAN NUCLEAR SOC | - |
dc.subject | FIELD EMITTERS | - |
dc.subject | BEAM | - |
dc.title | An Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography | - |
dc.type | Article | - |
dc.identifier.wosid | 000377974800024 | - |
dc.identifier.scopusid | 2-s2.0-84973299926 | - |
dc.type.rims | ART | - |
dc.citation.volume | 48 | - |
dc.citation.issue | 3 | - |
dc.citation.beginningpage | 799 | - |
dc.citation.endingpage | 804 | - |
dc.citation.publicationname | NUCLEAR ENGINEERING AND TECHNOLOGY | - |
dc.identifier.doi | 10.1016/j.net.2016.01.012 | - |
dc.contributor.localauthor | Cho, Sung-Oh | - |
dc.contributor.nonIdAuthor | Park, Han Beom | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | CNT Field Emitter | - |
dc.subject.keywordAuthor | Miniature X-ray Tube | - |
dc.subject.keywordAuthor | Radiography | - |
dc.subject.keywordAuthor | X-ray Image | - |
dc.subject.keywordPlus | FIELD EMITTERS | - |
dc.subject.keywordPlus | BEAM | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.