Proton-radiography-based quality assurance of proton range compensator

Cited 4 time in webofscience Cited 0 time in scopus
  • Hit : 268
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorPark, Seyjoonko
dc.contributor.authorJeong, Chiyoungko
dc.contributor.authorKang, Dong Yunko
dc.contributor.authorShin, Jae-ikko
dc.contributor.authorCho, Sungkooko
dc.contributor.authorPark, Jeong-Hoonko
dc.contributor.authorShin, Donghoko
dc.contributor.authorLim, Young Kyungko
dc.contributor.authorKim, Joo-Youngko
dc.contributor.authorMin, Byung Junko
dc.contributor.authorKwak, Jungwonko
dc.contributor.authorLee, Jiseocko
dc.contributor.authorCho, Seungryongko
dc.contributor.authorKim, Dae-Hyunko
dc.contributor.authorPark, Sung Yongko
dc.contributor.authorLee, Se Byeongko
dc.date.accessioned2016-07-07T07:03:31Z-
dc.date.available2016-07-07T07:03:31Z-
dc.date.created2013-11-04-
dc.date.created2013-11-04-
dc.date.created2013-11-04-
dc.date.issued2013-09-
dc.identifier.citationPHYSICS IN MEDICINE AND BIOLOGY, v.58, no.18, pp.6511 - 6523-
dc.identifier.issn0031-9155-
dc.identifier.urihttp://hdl.handle.net/10203/210208-
dc.description.abstractThe aim of this work was to study the feasibility of proton radiography (pRad) as a patient-specific range compensator (RC) quality assurance (QA) tool and to validate its clinical utility by performing QA on RCs having three kinds of possible defects. In order to achieve pRad for a single EBT film, proton beam currents were modulated with new weighting factors, maximizing the linearity of optical-density-to-thickness ratio. Two RCs, examined to be accurately manufactured as planned, were selected to estimate the feasibility of our pRad. The optical densities of the EBT film on which the RC was irradiated with the modulated proton beam were digitized to pixel values (pv) and then converted to thickness using a thickness-pv calibration curve. The thickness information on the pRad was compared with plan data that had been extracted from treatment planning system. The mean thickness difference (TD) over the flat RC regions was calculated as 0.39 mm, and the standard deviation as 0.22 mm, and the proton scattering effect was analyzed by step phantom measurement. Even proton scattering effected a TD of over 1 mm in the large gradient region, the percentage of pixels over the acceptance criterion was only within 1.11% and 3.49%, respectively, when a 1 mm distance to agreement tolerance limit was applied. The QA results for both precisely and imprecisely manufactured RCs demonstrated the high potential utility and clinical applicability of the pRad-based RC QA tool.-
dc.languageEnglish-
dc.publisherIOP PUBLISHING LTD-
dc.subjectGAFCHROMIC EBT FILM-
dc.subjectCOMPUTED-TOMOGRAPHY-
dc.subjectTHERAPY-
dc.subjectDOSIMETRY-
dc.subjectDENSITY-
dc.subjectBEAMS-
dc.subjectTOOL-
dc.titleProton-radiography-based quality assurance of proton range compensator-
dc.typeArticle-
dc.identifier.wosid000324573400018-
dc.identifier.scopusid2-s2.0-84884131796-
dc.type.rimsART-
dc.citation.volume58-
dc.citation.issue18-
dc.citation.beginningpage6511-
dc.citation.endingpage6523-
dc.citation.publicationnamePHYSICS IN MEDICINE AND BIOLOGY-
dc.identifier.doi10.1088/0031-9155/58/18/6511-
dc.contributor.localauthorCho, Seungryong-
dc.contributor.nonIdAuthorPark, Seyjoon-
dc.contributor.nonIdAuthorJeong, Chiyoung-
dc.contributor.nonIdAuthorKang, Dong Yun-
dc.contributor.nonIdAuthorShin, Jae-ik-
dc.contributor.nonIdAuthorCho, Sungkoo-
dc.contributor.nonIdAuthorPark, Jeong-Hoon-
dc.contributor.nonIdAuthorShin, Dongho-
dc.contributor.nonIdAuthorLim, Young Kyung-
dc.contributor.nonIdAuthorKim, Joo-Young-
dc.contributor.nonIdAuthorMin, Byung Jun-
dc.contributor.nonIdAuthorKwak, Jungwon-
dc.contributor.nonIdAuthorLee, Jiseoc-
dc.contributor.nonIdAuthorKim, Dae-Hyun-
dc.contributor.nonIdAuthorPark, Sung Yong-
dc.contributor.nonIdAuthorLee, Se Byeong-
dc.type.journalArticleArticle-
dc.subject.keywordPlusGAFCHROMIC EBT FILM-
dc.subject.keywordPlusCOMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusTHERAPY-
dc.subject.keywordPlusDOSIMETRY-
dc.subject.keywordPlusDENSITY-
dc.subject.keywordPlusBEAMS-
dc.subject.keywordPlusTOOL-
dc.subject.keywordPlusGAFCHROMIC EBT FILM-
dc.subject.keywordPlusCOMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusTHERAPY-
dc.subject.keywordPlusDOSIMETRY-
dc.subject.keywordPlusDENSITY-
dc.subject.keywordPlusBEAMS-
dc.subject.keywordPlusTOOL-
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 4 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0