A Flexible and Wearable Human Stress Monitoring Patch

Cited 93 time in webofscience Cited 87 time in scopus
  • Hit : 608
  • Download : 427
DC FieldValueLanguage
dc.contributor.authorYoon, Sunghyunko
dc.contributor.authorSim, Jai Kyoungko
dc.contributor.authorCho, Young-Hoko
dc.date.accessioned2016-06-30T00:33:48Z-
dc.date.available2016-06-30T00:33:48Z-
dc.date.created2016-04-19-
dc.date.created2016-04-19-
dc.date.issued2016-03-
dc.identifier.citationSCIENTIFIC REPORTS, v.6-
dc.identifier.issn2045-2322-
dc.identifier.urihttp://hdl.handle.net/10203/208652-
dc.description.abstractA human stress monitoring patch integrates three sensors of skin temperature, skin conductance, and pulsewave in the size of stamp (25 mm x 15 mm x 72 mu m) in order to enhance wearing comfort with small skin contact area and high flexibility. The skin contact area is minimized through the invention of an integrated multi-layer structure and the associated microfabrication process; thus being reduced to 1/125 of that of the conventional single-layer multiple sensors. The patch flexibility is increased mainly by the development of flexible pulsewave sensor, made of a flexible piezoelectric membrane supported by a perforated polyimide membrane. In the human physiological range, the fabricated stress patch measures skin temperature with the sensitivity of 0.31 Omega/degrees C, skin conductance with the sensitivity of 0.28 mu V/0.02 mu S, and pulse wave with the response time of 70 msec. The skin-attachable stress patch, capable to detect multimodal bio-signals, shows potential for application to wearable emotion monitoring-
dc.languageEnglish-
dc.publisherNATURE PUBLISHING GROUP-
dc.titleA Flexible and Wearable Human Stress Monitoring Patch-
dc.typeArticle-
dc.identifier.wosid000372607200001-
dc.identifier.scopusid2-s2.0-84961627363-
dc.type.rimsART-
dc.citation.volume6-
dc.citation.publicationnameSCIENTIFIC REPORTS-
dc.identifier.doi10.1038/srep23468-
dc.contributor.localauthorCho, Young-Ho-
dc.description.isOpenAccessY-
dc.type.journalArticleArticle-
dc.subject.keywordPlusHEART-RATE-VARIABILITY-
dc.subject.keywordPlusMENTAL STRESS-
dc.subject.keywordPlusTACTILE SENSORS-
dc.subject.keywordPlusPRESSURE SENSOR-
dc.subject.keywordPlusBLOOD-PRESSURE-
dc.subject.keywordPlusPULSE-
dc.subject.keywordPlusRESPONSES-
dc.subject.keywordPlusDESIGN-
dc.subject.keywordPlusDEVICE-
dc.subject.keywordPlusWORK-
Appears in Collection
BiS-Journal Papers(저널논문)
Files in This Item
94839.pdf(1.54 MB)Download
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 93 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0