Effects of interfacial layer wettability and thickness on the coating morphology and sirolimus release for drug-eluting stent

Cited 23 time in webofscience Cited 21 time in scopus
  • Hit : 319
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorBedair, Tarek M.ko
dc.contributor.authorYu, Seung Jungko
dc.contributor.authorIm, Sung Gapko
dc.contributor.authorPark, Bang Juko
dc.contributor.authorJoung, Yoon Kiko
dc.contributor.authorHan, Dong Keunko
dc.date.accessioned2016-04-20T06:10:44Z-
dc.date.available2016-04-20T06:10:44Z-
dc.date.created2015-11-18-
dc.date.created2015-11-18-
dc.date.issued2015-12-
dc.identifier.citationJOURNAL OF COLLOID AND INTERFACE SCIENCE, v.460, pp.189 - 199-
dc.identifier.issn0021-9797-
dc.identifier.urihttp://hdl.handle.net/10203/205138-
dc.description.abstractDrug-eluting stents (DESs) have been used to treat coronary artery diseases by placing in the arteries. However, current DESs still suffer from polymer coating defects such as delamination and peeling-off that follows stent deployment. Such coating defects could increase the roughness of DES and might act as a source of late or very late thrombosis and might increase the incident of restenosis. In this regard, we modified the cobalt-chromium (Co-Cr) alloy surface with hydrophilic poly(2-hydroxyethyl methacrylate) (PHEMA) or hydrophobic poly(2-hydroxyethyl methacrylate)-grafted-poly(caprolactone) (PHEMA-g-PCL) brushes. The resulting surfaces were biocompatible and biodegradable, which could act as anchoring layer for the drug-in-polymer matrix coating. The two modifications were characterized by ATR-FTIR, XPS, water contact angle measurements, SEM and AFM. On the control and modified Co-Cr samples, a sirolimus (SRL)-containing poly(D,L-lactide) (PDLLA) were ultrasonically spray-coated, and the drug release was examined for 8 weeks under physiological conditions. The results demonstrated that PHEMA as a primer coating improved the coating stability and degradation morphology, and drug release profile for short-term as compared to control Co-Cr, but fails after 7 weeks in physiological buffer. On the other hand, the hydrophobic PHEMA-g-PCL brushes not only enhanced the stability and degradation morphology of the PDLLA coating layer, but also sustained SRL release for long-term. At 8-week of release test, the surface morphologies and release profiles of coated PDLLA layers verified the beneficial effect of hydrophobic PCL brushes as well as their thickness on coating stability. Our study concludes that 200 nm thickness of PHEMA-g-PCL as interfacial layer affects the stability and degradation morphology of the biodegradable coating intensively to be applied for various biodegradable-based DESs.-
dc.languageEnglish-
dc.publisherACADEMIC PRESS INC ELSEVIER SCIENCE-
dc.subjectCHEMICAL-VAPOR-DEPOSITION-
dc.subjectIN-VITRO DEGRADATION-
dc.subjectPOLY(2-HYDROXYETHYL METHACRYLATE)-
dc.subjectMETAL-SURFACE-
dc.subjectHYDROGELS-
dc.subjectTITANIUM-
dc.subjectICVD-
dc.subjectTHROMBOGENICITY-
dc.subjectIMPLANTATION-
dc.subjectDURABILITY-
dc.titleEffects of interfacial layer wettability and thickness on the coating morphology and sirolimus release for drug-eluting stent-
dc.typeArticle-
dc.identifier.wosid000363077800023-
dc.identifier.scopusid2-s2.0-84940048168-
dc.type.rimsART-
dc.citation.volume460-
dc.citation.beginningpage189-
dc.citation.endingpage199-
dc.citation.publicationnameJOURNAL OF COLLOID AND INTERFACE SCIENCE-
dc.identifier.doi10.1016/j.jcis.2015.08.051-
dc.contributor.localauthorIm, Sung Gap-
dc.contributor.nonIdAuthorBedair, Tarek M.-
dc.contributor.nonIdAuthorPark, Bang Ju-
dc.contributor.nonIdAuthorJoung, Yoon Ki-
dc.contributor.nonIdAuthorHan, Dong Keun-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorDrug-eluting stent-
dc.subject.keywordAuthorBiodegradable polymer-
dc.subject.keywordAuthorRing-opening polymerization-
dc.subject.keywordAuthorPhoto-initiated chemical vapor deposition-
dc.subject.keywordAuthorPolymer brush-
dc.subject.keywordPlusCHEMICAL-VAPOR-DEPOSITION-
dc.subject.keywordPlusIN-VITRO DEGRADATION-
dc.subject.keywordPlusPOLY(2-HYDROXYETHYL METHACRYLATE)-
dc.subject.keywordPlusMETAL-SURFACE-
dc.subject.keywordPlusHYDROGELS-
dc.subject.keywordPlusTITANIUM-
dc.subject.keywordPlusICVD-
dc.subject.keywordPlusTHROMBOGENICITY-
dc.subject.keywordPlusIMPLANTATION-
dc.subject.keywordPlusDURABILITY-
Appears in Collection
CBE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 23 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0