COMPARISON OF GAS SYSTEM ANALYSIS CODE GAMMA+ TO S-CO2 COMPRESSOR TEST DATA

Cited 4 time in webofscience Cited 0 time in scopus
  • Hit : 288
  • Download : 76
DC FieldValueLanguage
dc.contributor.authorBae, Seong Junko
dc.contributor.authorAhn, Yoon Hanko
dc.contributor.authorLim, Hong Sikko
dc.contributor.authorCha, Jae Eunko
dc.contributor.authorLee, Jeong Ikko
dc.date.accessioned2016-04-18T05:54:48Z-
dc.date.available2016-04-18T05:54:48Z-
dc.date.created2015-12-15-
dc.date.created2015-12-15-
dc.date.created2015-12-15-
dc.date.created2015-12-15-
dc.date.issued2015-06-17-
dc.identifier.citationASME Turbo Expo 2015-
dc.identifier.urihttp://hdl.handle.net/10203/204816-
dc.description.abstractThe CO2 compressor control is one of the most important issues to operate a Supercritical CO2 (S-CO2) Brayton cycle with a high thermal efficiency because it is operated near the critical point to reduce the compressing work. Therefore, our research team has accumulated the CO2 compressor data from the S-CO2 compressor test facility called SCO2PE (Supercritical CO2 Pressurizing Experiment). The data can be obtained under various compressor inlet conditions, especially near the critical point of CO2. Despite the growing interest in the S-CO2 Brayton cycle, research on the cycle transient analysis, especially in case of CO2 compressor inlet condition variation, is still in its early stage. So, in this study, the validation and verification of the gas system transient analysis code GAMMA+ is carried out by utilizing the experimental data of SCO2PE. To simulate the SCO2PE by the GAMMA+ code, the code was revised to reflect the compressor performance and add an expansion valve option. Moreover, the NIST database was connected to the GAMMA+ code for more accurate CO2 properties near the critical point. Prior to the transient analysis with the whole SCO2PE loop, major components such as a compressor and a heat exchanger were separately tested with the steady state data of SCO2PE. The loss of cooling water accident was assumed as the transient situation by observing the operating condition variations of the SCO2PE while the mass flow rate of water loop was decreased. Thus, the experimental data of SCO2PE was compared with the revised GAMMA+ code under the planned transient.-
dc.languageEnglish-
dc.publisherASME-
dc.titleCOMPARISON OF GAS SYSTEM ANALYSIS CODE GAMMA+ TO S-CO2 COMPRESSOR TEST DATA-
dc.typeConference-
dc.identifier.wosid000374508400032-
dc.identifier.scopusid2-s2.0-84954305786-
dc.type.rimsCONF-
dc.citation.publicationnameASME Turbo Expo 2015-
dc.identifier.conferencecountryCN-
dc.identifier.conferencelocationPalais des Congress, Montreal-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.contributor.localauthorLee, Jeong Ik-
dc.contributor.nonIdAuthorBae, Seong Jun-
dc.contributor.nonIdAuthorAhn, Yoon Han-
dc.contributor.nonIdAuthorLim, Hong Sik-
dc.contributor.nonIdAuthorCha, Jae Eun-
Appears in Collection
NE-Conference Papers(학술회의논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 4 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0