DC magnetron sputter deposited (Pt/Co/Pt/Ni) multilayers which exhibited Curie temperatures in the range of 150-300 degrees C were studied as possible alternative multilayers for magneto-optical recording to the widely studied Co/Pt, whose Curie temperatures are in the range of 200-400 degrees C. These multilayers exhibited comparable magnetic and magneto-optical properties to Co/Pt multilayers with enhancement of the Kerr rotation at lower wavelengths and negligible Kerr ellipticity over a wide range of the spectrum. The dependence of the magnetic anisotropy on the thicknesses of nickel, cobalt, and platinum sublayers was studied. The surface anisotropies of nickel and cobalt were estimated as - 0.003 ergs/cm(2) and 0.027 ergs/cm(2) respectively and the total volume anisotropy due to Co and Ni is estimated as - 1.74 x 10(6) ergs/cm(3).
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Issue Date
1997-09
Language
English
Article Type
Article; Proceedings Paper
Keywords

RECORDING MATERIALS; CO/PT MULTILAYERS; CO

Citation

IEEE TRANSACTIONS ON MAGNETICS, v.33, no.5, pp.3667 - 3669

ISSN
0018-9464