Fluid flow and heat transfer characteristics of cross-cut heat sinks

Cited 40 time in webofscience Cited 42 time in scopus
  • Hit : 390
  • Download : 7
DC FieldValueLanguage
dc.contributor.authorKim, SungJinko
dc.contributor.authorKim, Tae Youngko
dc.date.accessioned2010-11-24T01:27:58Z-
dc.date.available2010-11-24T01:27:58Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2009-11-
dc.identifier.citationINTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, v.52, pp.5358 - 5370-
dc.identifier.issn0017-9310-
dc.identifier.urihttp://hdl.handle.net/10203/20324-
dc.description.abstractIn this study, effects of cross-cuts on the thermal performance of heat sinks under the parallel flow condition are experimentally studied. To find effects of the length, position, and number of cross-cuts, heat sinks with one or several cross-cuts ranging from 0.5 mm to 10 mm were fabricated. The pressure drop and the thermal resistance of the heat sinks are obtained in the range of 0.01 W<P(p) < 1 W. Experimental results show that among the many cross-cut design parameters, the cross-cut length has the most significant influence on the thermal performance of heat sinks. The results also show that heat sinks with a cross-cut are superior to heat sinks containing several cross-cuts in the thermal performance. Based on experimental results, the friction factor and Nusselt number correlations for heat sinks with a crosscut are suggested. Using the proposed correlations, thermal performances of cross-cut heat sinks are compared to those of optimized plate-fin and square pin-fin heat sinks under the constant pumping power condition. This comparison yields a contour map that suggests an optimum type of heat sink under the constraint of the fixed pumping power and fixed heat sink volume. The contour map shows that an optimized cross-cut heat sink outperforms optimized plate-fin and square pin-fin heat sinks when 0.04 < log L* < 1. (C) 2009 Elsevier Ltd. All rights reserved.-
dc.description.sponsorshipThis work was supported by the Korea Science and Engineering Foundation (KOSEF) through the National Research Lab. Program funded by the Ministry of Education, Science and Technology (No. M1060000022406J000022410).en
dc.languageEnglish-
dc.language.isoen_USen
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.subjectPLATE-FIN-
dc.subjectPERFORMANCE-
dc.subjectCHANNEL-
dc.titleFluid flow and heat transfer characteristics of cross-cut heat sinks-
dc.typeArticle-
dc.identifier.wosid000273358700010-
dc.identifier.scopusid2-s2.0-69949103833-
dc.type.rimsART-
dc.citation.volume52-
dc.citation.beginningpage5358-
dc.citation.endingpage5370-
dc.citation.publicationnameINTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER-
dc.identifier.doi10.1016/j.ijheatmasstransfer.2009.07.008-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.contributor.localauthorKim, SungJin-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorCross-cut heat sink-
dc.subject.keywordAuthorThermal optimization-
dc.subject.keywordPlusPLATE-FIN-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusCHANNEL-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 40 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0