dc.description.abstract | A label-free aptasensor for platelet-derived growth factor (PDGF) protein is reported. The aptasensor uses mixed self-assembled monolayers (SAMs) composed of a thiol-modified PDGF binding aptamer and 6-mercaptohexanol (MCH) on a gold electrode. The SAMs were characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV) before and after binding of the protein using [Fe(CN)(6)](3-/4-), a redox marker ion as an indicator for the formation of a protein-aptamer complex. The CVs at the PDGF modified electrode showed significant differences, such as changes in the peak currents and peak-to-peak separation, before and after binding of the target protein. The EIS spectra, in the form of Nyquist plots, were analyzed with a Randles circuit while the electron transfer resistance R-ct was used to monitor the binding of the target protein. The results showed that, without any modification to the aptamer, the target protein can be recognized effectively at the PDGF binding aptamer SAMs at the electrode surface. Control experiments using non-binding oligonucleotides assembled at the electrode surfaces also confirmed the results and showed that there was no formation of an aptamer-protein complex. The DPV signal at the aptamer functionalized electrode showed a linearly decreased marker ion peak current in a protein concentrations range of 1-40 nM. Thus, label-free detection of PDGF protein at an aptamer modified electrode has been demonstrated. (C) 2008 Elsevier B.V. All rights reserved. | - |
dc.description.sponsorship | This work was supported by the Korea Science and Engineering Foundation (KOSEF) grant funded by the Korea government (MOST) through the Bioelectronics Program (M10536000001-06N3600-00110) and the Basic Research Program (R01-2005-000-10503-0). | en |
dc.language | English | - |
dc.language.iso | en_US | en |
dc.publisher | ELSEVIER SCIENCE BV | - |
dc.subject | APTAMER-BASED SENSORS | - |
dc.subject | ELECTROCHEMICAL DETECTION | - |
dc.subject | IMPEDANCE SPECTROSCOPY | - |
dc.subject | GOLD NANOPARTICLES | - |
dc.subject | BIOLOGICAL-FLUIDS | - |
dc.subject | DNA | - |
dc.subject | AMPLIFICATION | - |
dc.subject | COMPLEX | - |
dc.subject | SWITCH | - |
dc.subject | TRANSDUCTION | - |
dc.title | Label-free aptasensor for platelet-derived growth factor (PDGF) protein | - |
dc.type | Article | - |
dc.identifier.wosid | 000255469700005 | - |
dc.identifier.scopusid | 2-s2.0-41349092692 | - |
dc.type.rims | ART | - |
dc.citation.volume | 613 | - |
dc.citation.issue | 2 | - |
dc.citation.beginningpage | 163 | - |
dc.citation.endingpage | 168 | - |
dc.citation.publicationname | ANALYTICA CHIMICA ACTA | - |
dc.identifier.doi | 10.1016/j.aca.2008.03.010 | - |
dc.embargo.liftdate | 9999-12-31 | - |
dc.embargo.terms | 9999-12-31 | - |
dc.contributor.localauthor | Kwak, Juhyoun | - |
dc.contributor.nonIdAuthor | Degefa, Tesfaye Hailu | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | aptamer | - |
dc.subject.keywordAuthor | target protein | - |
dc.subject.keywordAuthor | label-free | - |
dc.subject.keywordAuthor | aptasensor | - |
dc.subject.keywordPlus | APTAMER-BASED SENSORS | - |
dc.subject.keywordPlus | ELECTROCHEMICAL DETECTION | - |
dc.subject.keywordPlus | IMPEDANCE SPECTROSCOPY | - |
dc.subject.keywordPlus | GOLD NANOPARTICLES | - |
dc.subject.keywordPlus | BIOLOGICAL-FLUIDS | - |
dc.subject.keywordPlus | DNA | - |
dc.subject.keywordPlus | AMPLIFICATION | - |
dc.subject.keywordPlus | COMPLEX | - |
dc.subject.keywordPlus | SWITCH | - |
dc.subject.keywordPlus | TRANSDUCTION | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.