A novel approach to analysis of electroosmotic pumping through rectangular-shaped microchannels

Cited 19 time in webofscience Cited 22 time in scopus
  • Hit : 420
  • Download : 2
DC FieldValueLanguage
dc.contributor.authorMin, JYko
dc.contributor.authorKim, Dko
dc.contributor.authorKim, SungJinko
dc.date.accessioned2010-11-15T07:25:43Z-
dc.date.available2010-11-15T07:25:43Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2006-12-
dc.identifier.citationSENSORS AND ACTUATORS B-CHEMICAL, v.120, no.1, pp.305 - 312-
dc.identifier.issn0925-4005-
dc.identifier.urihttp://hdl.handle.net/10203/19942-
dc.description.abstractIn this paper, a simple but accurate modeling method for obtaining analytical solutions for the fundamental characteristics of electroosmotic flow through rectangular pumping channels without the Debye-Huckel approximation is presented. The Poisson-Boltzmann equation without the Debye-Huckel approximation for the electric potential distribution and the momentum equation for the velocity profile are averaged and solved analytically. To validate the modeling method proposed in the present work, electroosmotic flows through a rectangular capillary whose side is 50 pm are experimentally investigated. The zeta potential at the silica-potassium phosphate buffered saline interface is measured by the streaming potential technique. The pressure driven flow characteristics of and the maximum electroosmotic flow rate through the capillary are measured. By comparing these experimental data and numerical solutions for original governing equations with the analytical solutions, the present analytical method is validated. It is found that the present modeling method is applicable when the ratio of a half of the channel width to the electric double layer thickness is larger than 3. From a parametric study for various configurations of the pumping channel based on the analytical solutions, it is shown that the pumping power can be increased by one order of magnitude with decreasing channel width. (c) 2006 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.language.isoen_USen
dc.publisherELSEVIER SCIENCE SA-
dc.subjectCAPILLARY ELECTROPHORESIS-
dc.subjectDNA ANALYSIS-
dc.subjectMICROPUMP-
dc.subjectMICROSTRUCTURES-
dc.subjectINTEGRATION-
dc.subjectSIMULATION-
dc.subjectEFFICIENCY-
dc.subjectTRANSPORT-
dc.titleA novel approach to analysis of electroosmotic pumping through rectangular-shaped microchannels-
dc.typeArticle-
dc.identifier.wosid000241489300044-
dc.identifier.scopusid2-s2.0-33749236082-
dc.type.rimsART-
dc.citation.volume120-
dc.citation.issue1-
dc.citation.beginningpage305-
dc.citation.endingpage312-
dc.citation.publicationnameSENSORS AND ACTUATORS B-CHEMICAL-
dc.identifier.doi10.1016/j.snb.2006.02.028-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.contributor.localauthorKim, SungJin-
dc.contributor.nonIdAuthorMin, JY-
dc.contributor.nonIdAuthorKim, D-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorelectroosmotic pumping-
dc.subject.keywordAuthormicrochannel-
dc.subject.keywordAuthoraveraging technique-
dc.subject.keywordAuthoranalytical solutions-
dc.subject.keywordAuthorpumping power-
dc.subject.keywordPlusCAPILLARY ELECTROPHORESIS-
dc.subject.keywordPlusDNA ANALYSIS-
dc.subject.keywordPlusMICROPUMP-
dc.subject.keywordPlusMICROSTRUCTURES-
dc.subject.keywordPlusINTEGRATION-
dc.subject.keywordPlusSIMULATION-
dc.subject.keywordPlusEFFICIENCY-
dc.subject.keywordPlusTRANSPORT-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 19 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0