Development of neutron dark-field imaging technique with polychromatic neutron beam다색중성자빔을 이용한 중성자 다크필드 영상기술 연구

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 835
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorCho, Gyu-Seong-
dc.contributor.advisor조규성-
dc.contributor.authorKim, Jong-Yul-
dc.contributor.author김종열-
dc.date.accessioned2015-04-23T07:09:41Z-
dc.date.available2015-04-23T07:09:41Z-
dc.date.issued2014-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=591802&flag=dissertation-
dc.identifier.urihttp://hdl.handle.net/10203/197272-
dc.description학위논문(박사) - 한국과학기술원 : 원자력및양자공학과, 2014.8, [ viii, 92 p. ]-
dc.description.abstractGrating-based neutron phase-contrast and dark-field imaging techniques based on phase shift and amplitude effects have been developed over the past few years which were used for some scientific applications such as bulk magnetic material and microstructure studies. Neutron dark-field imaging has been demonstrated to be able to visualize the magnetic domains of magnetic materials owing to a strong dark-field signal from magnetic domain walls. Moreover, a three-dimensional image of magnetic domain structures within the bulk of FeSi crystals can be obtained using neutron dark-field tomography. Although neutron darkfield imaging shows a great potential in investigating internal magnetic domain structures, improved image quality is demanded for more detailed information. The established neutron grating interferometers at some research facilities were designed for neutrons having wavelengths above 4.0Å , and are usually tested with monochromatic or quasi-monochromatic neutrons. The reason why monochromatic or quasi-monochromatic neutrons are used is because they provide better contrast sensitivity and thus make it easier to model the interference effect of the system. Monochromatic or quasi-monochromatic neutrons, however, do not provide not only enough number of neutrons for imaging with a high spatial resolution but also give fast data acquisition time. This limitation is mainly due to the large number of neutrons lost during the monochromatization process. Limited neutron flux and detector resolution are one of the main challenges in making a neutron grating interferometer as an efficient measurement technique. To achieve high resolution neutron image with a short data acquisition time, it is natural to adopt polychromatic neutron beam without monochromatization. It is important to find the neutron grating interferometer with a maximum visibility to effectively use a polychromatic thermal neutron beam. To maximize the visibility performance, a gratingbased interf...eng
dc.languageeng-
dc.publisher한국과학기술원-
dc.subjectneutron imaging-
dc.subject가시도-
dc.subject공간분해능-
dc.subject다색중성자빔-
dc.subject다크필드 영상-
dc.subject중성자 영상-
dc.subjectdark-field imaging-
dc.subjectpolychromatic neutron beam-
dc.subjectspatial resolution-
dc.subjectvisibility-
dc.titleDevelopment of neutron dark-field imaging technique with polychromatic neutron beam-
dc.title.alternative다색중성자빔을 이용한 중성자 다크필드 영상기술 연구-
dc.typeThesis(Ph.D)-
dc.identifier.CNRN591802/325007 -
dc.description.department한국과학기술원 : 원자력및양자공학과, -
dc.identifier.uid020105047-
dc.contributor.localauthorCho, Gyu-Seong-
dc.contributor.localauthor조규성-
Appears in Collection
NE-Theses_Ph.D.(박사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0