Double-looped Mach-Zehnder interferometer for achieving multiple ring-down interferograms

Cited 1 time in webofscience Cited 2 time in scopus
  • Hit : 584
  • Download : 411
DC FieldValueLanguage
dc.contributor.authorKim, Jin Hwanko
dc.contributor.authorKwon, Won-Sikko
dc.contributor.authorLee, Hyubko
dc.contributor.authorKim, Kyung-Sooko
dc.contributor.authorKim, Soo-Hyunko
dc.date.accessioned2015-01-29T07:27:58Z-
dc.date.available2015-01-29T07:27:58Z-
dc.date.created2014-12-22-
dc.date.created2014-12-22-
dc.date.issued2014-11-
dc.identifier.citationOPTICS EXPRESS, v.22, no.23, pp.28353 - 28362-
dc.identifier.issn1094-4087-
dc.identifier.urihttp://hdl.handle.net/10203/193908-
dc.description.abstractWe put forward a double-looped Mach-Zehnder interferometer for acquiring continuous ring-down interferograms with two fiber-loop cavities with slightly different optical path lengths. Each group of pulses through the sample and reference loops creates a ring-down pulse train with equal time intervals in Vernier fashion, and interferes with each other to produce multiple ring-down interferograms successively by scanning of a delay line. The system requires a scanning range of only a few millimeters to obtain multiple ring-down interferograms. In a proof-of-concept demonstration, the intrinsic losses of two loops are estimated. The measured combined-loss of both loops is compared to the sum of the loop losses measured separately with a conventional fiber-loop ring-down system. The result obtained using the proposed system exhibits a difference of only 0.06 dB with that of the reference system.-
dc.languageEnglish-
dc.publisherOPTICAL SOC AMER-
dc.subjectVERNIER OPERATION-
dc.subjectFIBER-
dc.subjectSPECTROSCOPY-
dc.subjectSENSORS-
dc.subjectRESONATORS-
dc.subjectLASER-
dc.subjectAMPLIFIER-
dc.titleDouble-looped Mach-Zehnder interferometer for achieving multiple ring-down interferograms-
dc.typeArticle-
dc.identifier.wosid000345268500058-
dc.identifier.scopusid2-s2.0-84913534832-
dc.type.rimsART-
dc.citation.volume22-
dc.citation.issue23-
dc.citation.beginningpage28353-
dc.citation.endingpage28362-
dc.citation.publicationnameOPTICS EXPRESS-
dc.identifier.doi10.1364/OE.22.028353-
dc.contributor.localauthorKim, Kyung-Soo-
dc.contributor.localauthorKim, Soo-Hyun-
dc.description.isOpenAccessY-
dc.type.journalArticleArticle-
dc.subject.keywordPlusVERNIER OPERATION-
dc.subject.keywordPlusFIBER-
dc.subject.keywordPlusSPECTROSCOPY-
dc.subject.keywordPlusSENSORS-
dc.subject.keywordPlusRESONATORS-
dc.subject.keywordPlusLASER-