An electrochemical immunosensor using ferrocenyl-tethered dendrimer

Cited 47 time in webofscience Cited 49 time in scopus
  • Hit : 416
  • Download : 675
DC FieldValueLanguage
dc.contributor.authorKwon, SJko
dc.contributor.authorKim, Eko
dc.contributor.authorYang, Hko
dc.contributor.authorKwak, Juhyounko
dc.date.accessioned2010-09-08T06:53:51Z-
dc.date.available2010-09-08T06:53:51Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2006-
dc.identifier.citationANALYST, v.131, no.3, pp.402 - 406-
dc.identifier.issn0003-2654-
dc.identifier.urihttp://hdl.handle.net/10203/19329-
dc.description.abstractWe report here an enzyme-amplified, sandwich-type immunosensor for detecting the biospecific interaction between an antibody and antigen using redox mediation. We employed biotin/anti-biotin IgG as a model immunosensing pair. Partially ferrocenyl-tethered dendrimer (Fc-D), whose ferrocene moiety acts as a redox mediator, was immobilized to the electrode surface by covalent binding between the dendrimer amines and the carboxylic acids of a self-assembled monolayer. The unreacted amines of the immobilized Fc-D were modified with biotin groups to allow the specific binding of goat anti-biotin IgG. Rabbit anti-goat IgG-conjugated alkaline phosphatase was bound to goat anti-biotin IgG to catalyze conversion of p-aminophenyl phosphate monohydrate to p-aminophenol. This product is oxidized to quinoimide by the reduction of ferrocenium back to ferrocene, producing an electrocatalytic anodic current. Cyclic voltammograms and surface plasmon resonance experiments showed that the binding of nonspecific proteins is not significant on the biotinylated Fc-D surface. We also examined the change in peak current according to the concentration of anti- biotin IgG and found that the detection range of this immunosensing scheme is between 0.1 and 30 mu g mL(-1).-
dc.languageEnglish-
dc.publisherROYAL SOC CHEMISTRY-
dc.subjectSELF-ASSEMBLED MONOLAYERS-
dc.subjectSURFACE-PLASMON RESONANCE-
dc.subjectELECTRODE-
dc.subjectASSAY-
dc.subjectDNA-
dc.subjectTRANSDUCTION-
dc.subjectIMMUNOASSAY-
dc.subjectSUBSTRATE-
dc.subjectDEVICES-
dc.subjectSYSTEMS-
dc.titleAn electrochemical immunosensor using ferrocenyl-tethered dendrimer-
dc.typeArticle-
dc.identifier.wosid000235992400007-
dc.identifier.scopusid2-s2.0-33644615767-
dc.type.rimsART-
dc.citation.volume131-
dc.citation.issue3-
dc.citation.beginningpage402-
dc.citation.endingpage406-
dc.citation.publicationnameANALYST-
dc.identifier.doi10.1039/b509969b-
dc.contributor.localauthorKwak, Juhyoun-
dc.contributor.nonIdAuthorKwon, SJ-
dc.contributor.nonIdAuthorKim, E-
dc.contributor.nonIdAuthorYang, H-
dc.type.journalArticleArticle-
dc.subject.keywordPlusSELF-ASSEMBLED MONOLAYERS-
dc.subject.keywordPlusSURFACE-PLASMON RESONANCE-
dc.subject.keywordPlusELECTRODE-
dc.subject.keywordPlusASSAY-
dc.subject.keywordPlusDNA-
dc.subject.keywordPlusTRANSDUCTION-
dc.subject.keywordPlusIMMUNOASSAY-
dc.subject.keywordPlusSUBSTRATE-
dc.subject.keywordPlusDEVICES-
dc.subject.keywordPlusSYSTEMS-
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 47 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0