Vacuum insulation properties of glass wool and opacified fumed silica under variable pressing load and vacuum level

Cited 37 time in webofscience Cited 41 time in scopus
  • Hit : 739
  • Download : 26
DC FieldValueLanguage
dc.contributor.authorKim, Jongminko
dc.contributor.authorSong, Tae-Hoko
dc.date.accessioned2014-09-01T07:26:49Z-
dc.date.available2014-09-01T07:26:49Z-
dc.date.created2013-09-26-
dc.date.created2013-09-26-
dc.date.issued2013-09-
dc.identifier.citationINTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, v.64, pp.783 - 791-
dc.identifier.issn0017-9310-
dc.identifier.urihttp://hdl.handle.net/10203/189256-
dc.description.abstractInsulation properties of glass wool (GW) and opacified fumed silica (OFS) as fillers of vacuum insulation panel are experimentally investigated for variable pressing load and vacuum level. Density change of the specimen as a function of the pressing force is measured. The thermal conductivity at center of panel is measured under various vacuum levels and pressing loads. To evaluate the radiative conductivity separately, the diffusion approximation is adopted and the extinction coefficient is measured by an FT-IR apparatus. As the density increases, the solid conductivity increases, while the radiative conductivity decreases to have their sum increased. Pore size is inversely proportional to the density of the material; however, the relation is not consistent in the case of OFS at very low density because of the highly heterogeneous porous structure at that density. Comparing the materials in terms of initial insulation per, formance at center of panel, we find that GW is superior at low pressing load and the other one is better at high pressing load. Also, OFS turns out to have a longer service-life. (C) 2013 Elsevier Ltd. All rights reserved.-
dc.languageEnglish-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.subjectTHERMAL-CONDUCTIVITY-
dc.subjectHEAT-TRANSFER-
dc.subjectFIBROUS INSULATION-
dc.subjectAEROGEL POWDERS-
dc.subjectPANELS-
dc.subjectTEMPERATURE-
dc.titleVacuum insulation properties of glass wool and opacified fumed silica under variable pressing load and vacuum level-
dc.typeArticle-
dc.identifier.wosid000323236900076-
dc.identifier.scopusid2-s2.0-84878691871-
dc.type.rimsART-
dc.citation.volume64-
dc.citation.beginningpage783-
dc.citation.endingpage791-
dc.citation.publicationnameINTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER-
dc.identifier.doi10.1016/j.ijheatmasstransfer.2013.05.012-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.contributor.localauthorSong, Tae-Ho-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorVacuum insulation panel-
dc.subject.keywordAuthorFumed silica-
dc.subject.keywordAuthorGlass wool-
dc.subject.keywordAuthorThermal conductivity-
dc.subject.keywordAuthorPressing load-
dc.subject.keywordPlusTHERMAL-CONDUCTIVITY-
dc.subject.keywordPlusHEAT-TRANSFER-
dc.subject.keywordPlusFIBROUS INSULATION-
dc.subject.keywordPlusAEROGEL POWDERS-
dc.subject.keywordPlusPHENOLIC FOAM-
dc.subject.keywordPlusPANELS-
dc.subject.keywordPlusTEMPERATURE-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 37 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0