Estimation of the flow profile correction factor of a transit-time ultrasonic flow meter for the feedwater flow measurement in a nuclear power plant

Cited 14 time in webofscience Cited 0 time in scopus
  • Hit : 1094
  • Download : 1153
DC FieldValueLanguage
dc.contributor.authorJung, JCko
dc.contributor.authorSeong, Poong-Hyunko
dc.date.accessioned2007-10-15T07:22:05Z-
dc.date.available2007-10-15T07:22:05Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2005-06-
dc.identifier.citationIEEE TRANSACTIONS ON NUCLEAR SCIENCE, v.52, no.3, pp.714 - 718-
dc.identifier.issn0018-9499-
dc.identifier.urihttp://hdl.handle.net/10203/1720-
dc.description.abstractA new method to estimate the flow profile correction factor (FPCF) for a transit-time ultrasonic flow meter (UFM) having a diametral transducer configuration is introduced in this work. For the adaptation of a diametral UFM for a feedwater measurement, the optimized flow profile correction factor is obtained through experiments and a simulation in actual flow conditions. The log function curve fitting is performed on a combined data set; the velocity ratio of UFM reading versus standard fluid measurement at low flow velocity, UFM reading versus standard fluid measurement at medium flow velocity, and UFM reading versus clean Venturi measurement at high flow velocity. Through an uncertainty analysis, the uncertainty of the FPCF is calculated. The resultant uncertainty of the new FPCF is 0.335%. This value is approximately half the value presented by UFM manufacturers. By adaptation of a diametral UFM with the new FPCF proposed in this work, feedwater flow measurement in nuclear power plants (NPPs) can be easily performed at lower cost than either chordal or cross-correlation UFM.-
dc.languageEnglish-
dc.language.isoen_USen
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.titleEstimation of the flow profile correction factor of a transit-time ultrasonic flow meter for the feedwater flow measurement in a nuclear power plant-
dc.typeArticle-
dc.identifier.wosid000230766600004-
dc.identifier.scopusid2-s2.0-23844443495-
dc.type.rimsART-
dc.citation.volume52-
dc.citation.issue3-
dc.citation.beginningpage714-
dc.citation.endingpage718-
dc.citation.publicationnameIEEE TRANSACTIONS ON NUCLEAR SCIENCE-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.contributor.localauthorSeong, Poong-Hyun-
dc.contributor.nonIdAuthorJung, JC-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorflow profile correction factor (FPCF)-
dc.subject.keywordAuthortransittime-
dc.subject.keywordAuthorultrasonic flow meter (UFM)-
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 14 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0