dc.description.abstract | Non-circular scanning geometries such as helix or circular sinusoid have been used or proposed for cone-beam computed tomography (CBCT), because they provide sufficient data for numerically stable and exact image reconstruction within the scanned volume. Analytic algorithms have been developed for image reconstruction from cone-beam data acquired with a full-scan circular sinusoidal trajectory. In this work, we propose an innovative imaging approach in which a reduced-scan circular sinusoidal trajectory is used for acquiring data sufficient for exact 3D image reconstruction. A filtered backprojection (FBP) algorithm based on Pack-Noo's reconstruction formula is applied for image reconstruction in reduced-scan circular sinusoidal scans. We have conducted numerical studies to demonstrate the reduced-scan approach and to validate the FBP reconstruction algorithm in the proposed approach. The proposed scanning method can contribute to increasing the throughput of a scanner, while improving the image quality compared to a conventional circular scan. | - |
dc.language | English | - |
dc.publisher | IOS PRESS | - |
dc.subject | FILTERED BACKPROJECTION | - |
dc.subject | COMPUTED-TOMOGRAPHY | - |
dc.subject | PI-LINES | - |
dc.subject | FAN-BEAM | - |
dc.subject | ALGORITHMS | - |
dc.subject | PROJECTION | - |
dc.subject | NOISE | - |
dc.title | Image reconstruction in reduced circular sinusoidal cone-beam CT | - |
dc.type | Article | - |
dc.identifier.wosid | 000272194900001 | - |
dc.identifier.scopusid | 2-s2.0-73649128442 | - |
dc.type.rims | ART | - |
dc.citation.volume | 17 | - |
dc.citation.issue | 3 | - |
dc.citation.beginningpage | 189 | - |
dc.citation.endingpage | 205 | - |
dc.citation.publicationname | JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY | - |
dc.identifier.doi | 10.3233/XST-2009-0222 | - |
dc.contributor.localauthor | Cho, Seungryong | - |
dc.contributor.nonIdAuthor | Xia, Dan | - |
dc.contributor.nonIdAuthor | Pan, Xiaochuan | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | Reduced-scan | - |
dc.subject.keywordAuthor | circular sinusoidal trajectory | - |
dc.subject.keywordAuthor | cone-beam | - |
dc.subject.keywordAuthor | computed tomography | - |
dc.subject.keywordPlus | FILTERED BACKPROJECTION | - |
dc.subject.keywordPlus | COMPUTED-TOMOGRAPHY | - |
dc.subject.keywordPlus | PI-LINES | - |
dc.subject.keywordPlus | FAN-BEAM | - |
dc.subject.keywordPlus | ALGORITHMS | - |
dc.subject.keywordPlus | PROJECTION | - |
dc.subject.keywordPlus | NOISE | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.