Evaluation of the thermal efficiency and a cost analysis of different types of ground heat exchangers in energy piles

Cited 71 time in webofscience Cited 67 time in scopus
  • Hit : 551
  • Download : 0
This paper presents an experimental and numerical study of the results of a thermal performance test using precast high-strength concrete (PHC) energy piles with W and coil-type ground heat exchangers (GHEs). In-situ thermal performance tests (TPTs) were conducted for four days under an intermittent operation condition (8 h on; 16 h off) on W and coil-type PHC energy piles installed in a partially saturated weathered granite soil deposit. In addition, three-dimensional finite element analyses were conducted and the results were compared with the four-day experimental results. The heat exchange rates were also predicted for three months using the numerical analysis. The heat exchange rate of the coil-type GHE showed 10-15% higher efficiency compared to the W-type GHE in the energy pile. However, in considering the cost for the installation of the heat exchanger and cement grouting the additional cost of W-type GHE in energy pile was 200-250% cheaper than coil-type GHE under the condition providing equivalent thermal performance. Furthermore, the required lengths of the W, 3U and coil-type GHEs in the energy piles were calculated based on the design process of Kavanaugh and Rafferty. The additional cost for the W and 3U types of GHEs were also 200-250% lower than that of the coil-type GHE. However, the required number of piles was much less with the coil-type GHE as compared to the W and 3U types of GHEs. They are advantageous in terms of the construction period, and further, selecting the coil-type GHE could be a viable option when there is a limitation in the number of piles in consideration of the scale of the building.
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Issue Date
2015-11
Language
English
Article Type
Article
Keywords

PUMP SYSTEMS; IN-SITU; PERFORMANCE; TEMPERATURE; MODEL; FOUNDATION; BEHAVIOR

Citation

ENERGY CONVERSION AND MANAGEMENT, v.105, pp.393 - 402

ISSN
0196-8904
DOI
10.1016/j.enconman.2015.08.002
URI
http://hdl.handle.net/10203/205195
Appears in Collection
CE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.