덕트 유동에서 증발을 수반하는 액상 스프레이의 혼합 특성에 대한 실험적 연구An experimental study on the mixing of evaporating liquid spray in a duct flow

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 539
  • Download : 0
High temperature furnaces such as power plant and incinerator contribute considerable part of NOx generation and face urgent demand of De-NOx system. Reducing agent is injected into the flue gas flow to activate do-NOx system. Almost SCR system adopt vaporized ammonia injection system. Vaporizer, dilution system and additional space are needed to gasify and inject ammonia. Liquid spray injection system can simplify and economize post-treatment system of flue gas. In this study, mixing caused by gas or liquid injection of reducing agent into flue gas duct was investigated experimentally. Carbonated water was used as tracer and simulated agent and mixing of liquid spray in a duct flow was studied. To achieve that, the angle of attack of static mixer is simulated and $CO2 concentration is measured.
Publisher
한국액체미립화학회
Issue Date
2006-03
Language
Korean
Citation

한국액체미립화 학회지, v.11, no.1, pp.30 - 38

ISSN
1226-2277
URI
http://hdl.handle.net/10203/92215
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0