DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Youngbae | ko |
dc.contributor.author | Shin, HoChul | ko |
dc.contributor.author | Choi, Donk | ko |
dc.contributor.author | Albert, Carolyne | ko |
dc.contributor.author | Yoon, Yong-San | ko |
dc.date.accessioned | 2013-03-07T21:52:57Z | - |
dc.date.available | 2013-03-07T21:52:57Z | - |
dc.date.created | 2012-02-06 | - |
dc.date.created | 2012-02-06 | - |
dc.date.issued | 2008-04 | - |
dc.identifier.citation | JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, v.130, no.2 | - |
dc.identifier.issn | 0148-0731 | - |
dc.identifier.uri | http://hdl.handle.net/10203/91465 | - |
dc.description.abstract | Large interfacial gaps between the stem and the bone in cementless total hip arthroplasty may prevent successful bone ingrowth at the sites, and can also be a passage for wear particles. Furthermore, interfacial gaps between the stem and the bone are believed to compromise the primary stability of the implant. Thus, a broaching method that serves to reduce gaps is expected to give clinically preferable results. A modified broach system with a canal guide is introduced to enhance the accuracy of femoral canal shaping in comparison with the conventional broach system for a Versys (TM) fibermetal taper stem. The primary stability of the hip systems and the ratios of the stem surface in contact with the femur were measured in a composite femur model. With the conventional method, an average of 67% of the stem. surface was shown to be in contact with the bone, and an average stem micromotion/migration of 35 mu m/290 mu m was observed under 1000 cycles of stair climbing loads. With the modified method, the stern-bone contact ratio significantly increased to 82% (p < 0.05), and the average micromotion/migration reduced to 29 mu m/49 mu m, respectively (p < 0.05 for migration). Our finite element models of the hip systems supported that the difference in micromotion could be attributed to the difference in interfacial contact. Interfacial gaps occurring with the conventional broach system were effectively reduced by the proposed method, resulting in improved primary,stability. | - |
dc.language | English | - |
dc.publisher | ASME-AMER SOC MECHANICAL ENG | - |
dc.subject | TOTAL HIP-ARTHROPLASTY | - |
dc.subject | FEMORAL STEMS | - |
dc.subject | IN-VITRO | - |
dc.subject | MANUAL IMPLANTATION | - |
dc.subject | BONE INGROWTH | - |
dc.subject | FIXATION | - |
dc.subject | MOTION | - |
dc.subject | FEMUR | - |
dc.subject | REPLACEMENT | - |
dc.subject | MICROMOTION | - |
dc.title | Primary stability of cementless stem in THA improved with reduced interfacial gaps | - |
dc.type | Article | - |
dc.identifier.wosid | 000255902000008 | - |
dc.identifier.scopusid | 2-s2.0-47149101066 | - |
dc.type.rims | ART | - |
dc.citation.volume | 130 | - |
dc.citation.issue | 2 | - |
dc.citation.publicationname | JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | - |
dc.identifier.doi | 10.1115/1.2898761 | - |
dc.contributor.localauthor | Yoon, Yong-San | - |
dc.contributor.nonIdAuthor | Shin, HoChul | - |
dc.contributor.nonIdAuthor | Albert, Carolyne | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | femoral canal preparation | - |
dc.subject.keywordAuthor | primary stability | - |
dc.subject.keywordAuthor | interfacial gap | - |
dc.subject.keywordAuthor | total hip arthroplasty | - |
dc.subject.keywordAuthor | canal guide | - |
dc.subject.keywordPlus | TOTAL HIP-ARTHROPLASTY | - |
dc.subject.keywordPlus | FEMORAL STEMS | - |
dc.subject.keywordPlus | IN-VITRO | - |
dc.subject.keywordPlus | MANUAL IMPLANTATION | - |
dc.subject.keywordPlus | BONE INGROWTH | - |
dc.subject.keywordPlus | FIXATION | - |
dc.subject.keywordPlus | MOTION | - |
dc.subject.keywordPlus | FEMUR | - |
dc.subject.keywordPlus | REPLACEMENT | - |
dc.subject.keywordPlus | MICROMOTION | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.