Mechanical aspects of degree of cement bonding and implant wedge effect

Cited 5 time in webofscience Cited 0 time in scopus
  • Hit : 614
  • Download : 0
Background. The degree of bonding between the femoral stem and cement in total hip replacement remains controversial. Our objective was to determine the wedge effect by debonding and stem taper angle on the structural behavior of axisymmetric stem-cement-bone cylinder models. Methods. Stainless steel tapered plugs with a rough (i.e. bonded) or smooth (i.e. debonded) surface finish were used to emulate the femoral stem. Three different stem taper angles (5 degrees, 7.5 degrees, 10 degrees) were used for the debonded constructs. Non-tapered and tapered (7.5 degrees) aluminum cylindrical shells were used to emulate the diaphyseal and metaphyseal segments of the femur. The cement-aluminum cylinder interface was designed to have a shear strength that simulated bone-cement interfaces (similar to 8 MPa). The test involved applying axial compression at a rate of 0.02 mm/s until failure. Six specimens were tested for each combination of the variables. Finite element analysis was used to enhance the understanding of the wedge effect. Findings. The debonded stems sustained about twice as much load as the bonded stem, regardless of taper angle. The metaphyseal model carried 35-50% greater loads than the diaphyseal models and the stem taper produced significant differences. Based on the finite element analysis, failure was most probably by shear at the cement-bone interface. Interpretation. Our results in this simplified model suggest that smooth (i.e. debonded) stems have greater failure loads and will incur less slippage or shear failure at the cement-bone interface than rough (i.e. bonded) stems. (C) 2008 Elsevier Ltd. All rights reserved.
Publisher
ELSEVIER SCI LTD
Issue Date
2008-11
Language
English
Article Type
Article
Keywords

TOTAL HIP-REPLACEMENT; FEMORAL COMPONENTS; BONE INTERFACE; SURFACE-ROUGHNESS; CHARNLEY ELITE; STEMS; ARTHROPLASTY; FAILURE; PROSTHESIS; SUBSIDENCE

Citation

CLINICAL BIOMECHANICS, v.23, no.9, pp.1141 - 1147

ISSN
0268-0033
DOI
10.1016/j.clinbiomech.2008.05.003
URI
http://hdl.handle.net/10203/91400
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 5 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0