Hybrid control strategy for seismic protection of a benchmark cable-stayed bridge

Cited 28 time in webofscience Cited 0 time in scopus
  • Hit : 356
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorPark, KSko
dc.contributor.authorJung, Hyung-Joko
dc.contributor.authorLee, In Wonko
dc.date.accessioned2013-03-04T17:29:57Z-
dc.date.available2013-03-04T17:29:57Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2003-03-
dc.identifier.citationENGINEERING STRUCTURES, v.25, pp.405 - 417-
dc.identifier.issn0141-0296-
dc.identifier.urihttp://hdl.handle.net/10203/83460-
dc.description.abstractThis paper presents a hybrid control strategy for seismic protection of a benchmark cable-stayed bridge, which is provided as a testbed structure for the development of strategies for the control of cable-stayed bridges. In this study, a hybrid control system is composed of a passive control system to reduce the earthquake-induced forces in the structure and an active control system to further reduce the bridge responses, especially deck displacements. Conventional base isolation devices such as lead rubber bearings are used for the passive control design. For the active control design, ideal hydraulic actuators are used and an H-2/LQG control algorithm is adopted. Numerical simulation results show that the performance of the proposed hybrid control strategy is superior to that of the passive control strategy and slightly better than that of the active control strategy. The hybrid control method is also more reliable than the fully active control method due to the passive control part. Therefore, the proposed control strategy could be effectively used in seismically excited cable-stayed bridges. (C) 2003 Elsevier Science Ltd. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER SCI LTD-
dc.subjectVIBRATION CONTROL-
dc.titleHybrid control strategy for seismic protection of a benchmark cable-stayed bridge-
dc.typeArticle-
dc.identifier.wosid000181088500001-
dc.identifier.scopusid2-s2.0-0037367950-
dc.type.rimsART-
dc.citation.volume25-
dc.citation.beginningpage405-
dc.citation.endingpage417-
dc.citation.publicationnameENGINEERING STRUCTURES-
dc.contributor.localauthorJung, Hyung-Jo-
dc.contributor.nonIdAuthorPark, KS-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorhybrid control strategy-
dc.subject.keywordAuthorbase isolation system-
dc.subject.keywordAuthorH-2/LQG control algorithm-
dc.subject.keywordAuthorbenchmark control problem-
dc.subject.keywordAuthorseismic response control-
dc.subject.keywordPlusVIBRATION CONTROL-
Appears in Collection
CE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 28 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0