Measurement of the degree of cure of carbon fiber epoxy composite materials

Cited 37 time in webofscience Cited 0 time in scopus
  • Hit : 408
  • Download : 0
In this study, a dielectric cure monitoring system which consists of an electric circuit, a sensor and a personal computer was developed to on-line monitor the dielectric properties of carbon fiber epoxy composite materials. Also, the kinetic model of carbon fiber epoxy composite materials was developed by curve fitting of the differential scanning calorimetry (DSC) data. The start and end points of cure and the relationship between the dissipation factor and the degree of cure were obtained by comparing the dissipation factor from the dielectric properties with the degree of cure from the DSC data. The relationship between the dissipation factor and the degree of cure was tested under various temperature profiles.
Publisher
TECHNOMIC PUBL CO INC
Issue Date
1996
Language
English
Article Type
Article
Keywords

RESIN; KINETICS; VISCOSITY

Citation

JOURNAL OF COMPOSITE MATERIALS, v.30, no.13, pp.1436 - 1457

ISSN
0021-9983
URI
http://hdl.handle.net/10203/76603