Simultaneous Electrical Bio-Impedance Plethysmography at Different Body Parts: Continuous and Non-Invasive Monitoring of Pulse Wave Velocity

Cited 14 time in webofscience Cited 0 time in scopus
  • Hit : 226
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorLee, Kwonjoonko
dc.contributor.authorYoo, Hoi-Junko
dc.date.accessioned2021-12-21T06:41:27Z-
dc.date.available2021-12-21T06:41:27Z-
dc.date.created2021-12-20-
dc.date.created2021-12-20-
dc.date.issued2021-10-
dc.identifier.citationIEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, v.15, no.5, pp.1027 - 1038-
dc.identifier.issn1932-4545-
dc.identifier.urihttp://hdl.handle.net/10203/290818-
dc.description.abstractA simultaneous and time-synchronized electrical bio-impedance plethysmography (BPG) sensor system is implemented for long-term, continuous, and non-invasive measurement of arterial pulse wave velocity (PWV). The proposed BPG sensor system electrically separates each ground plane of two BPG channels and controller, and the two different BPG channels are time-synchronized by the controller transmitting periodic pulse signal to the two BPG channels. Furthermore, net parasitic capacitance between the ground planes is minimized by removing isolated DC-DC converter, limiting the number of digital capacitive isolators, and adopting optimal layout of the ground planes. The proposed sensor system is integrated on 278cm(2) printed circuit board. The sensor system consumes 0.35 W/channel, and outstanding channel-to-channel isolation is expected by coupling factor performance of -77.7 dB. In addition, modified electrode configuration for BPG at chest drastically reduces baseline wandering by respiratory motion artifact, thereby further facilitating long-term, continuous, and non-invasive PWV measurement. As a result, long-term, continuous, and non-invasive PWV measurement more than 95 minutes is successfully performed to pave the way for developing pulse transit time (PTT)-based cuff-less blood pressure (BP) estimation technique.-
dc.languageEnglish-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.titleSimultaneous Electrical Bio-Impedance Plethysmography at Different Body Parts: Continuous and Non-Invasive Monitoring of Pulse Wave Velocity-
dc.typeArticle-
dc.identifier.wosid000728926000019-
dc.identifier.scopusid2-s2.0-85115685180-
dc.type.rimsART-
dc.citation.volume15-
dc.citation.issue5-
dc.citation.beginningpage1027-
dc.citation.endingpage1038-
dc.citation.publicationnameIEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS-
dc.identifier.doi10.1109/TBCAS.2021.3115021-
dc.contributor.localauthorYoo, Hoi-Jun-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorBiomedical measurement-
dc.subject.keywordAuthorCurrent measurement-
dc.subject.keywordAuthorVoltage measurement-
dc.subject.keywordAuthorElectrodes-
dc.subject.keywordAuthorPollution measurement-
dc.subject.keywordAuthorPlethysmography-
dc.subject.keywordAuthorArteries-
dc.subject.keywordAuthorArterial pulse wave-
dc.subject.keywordAuthorarterial pressure pulse wave-
dc.subject.keywordAuthorarterial volume pulse wave-
dc.subject.keywordAuthorelectrical bio-impedance plethysmography-
dc.subject.keywordAuthorimpedance cardiography-
dc.subject.keywordAuthorgalvanic isolation-
dc.subject.keywordAuthorpulse wave velocity-
dc.subject.keywordAuthorpulse transit time-
dc.subject.keywordAuthorrespiratory motion artifact-
dc.subject.keywordAuthornon-invasive monitoring-
dc.subject.keywordPlusBLOOD-PRESSURE-
dc.subject.keywordPlusHEART-RATE-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 14 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0