Study on ZnS(Ag) for alpha spectrometer using silicon based photo sensor

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 460
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKim, H.ko
dc.contributor.authorPark, K.ko
dc.contributor.authorHan, B.ko
dc.contributor.authorChoi, K. D.ko
dc.contributor.authorCho, Gyuseongko
dc.contributor.authorChang, H.ko
dc.date.accessioned2021-02-15T07:50:05Z-
dc.date.available2021-02-15T07:50:05Z-
dc.date.created2021-02-08-
dc.date.issued2020-10-
dc.identifier.citationJOURNAL OF INSTRUMENTATION, v.15, no.10, pp.P10020-
dc.identifier.issn1748-0221-
dc.identifier.urihttp://hdl.handle.net/10203/280725-
dc.description.abstractThe measuring of alpha particles is essential in many research fields such as radiation safety, health science, high energy, and nuclear physics. One of the most hazardous background radiation sources, radon, emits alpha particles, and damages lungs. Thus, the measurement of alpha particles in air correlates with the amount of radon and indicates when to ventilate the air. To detect alpha particles decayed from radon, a silicon photon multiplier (SiPM) in the shape of a multipixel photon counter (MPPC) and a scintillator optimized for zinc sulfide phosphor [ZnS(Ag)] alpha measurement were used. In this study, a dedicated amplifier was designed. The change in the pulse shape owing to operational amplifier, feedback resistor, and capacitor affect were studied and compared to that of a photo multiplier tube (PMT).-
dc.languageEnglish-
dc.publisherIOP PUBLISHING LTD-
dc.titleStudy on ZnS(Ag) for alpha spectrometer using silicon based photo sensor-
dc.typeArticle-
dc.identifier.wosid000608484200006-
dc.identifier.scopusid2-s2.0-85094675429-
dc.type.rimsART-
dc.citation.volume15-
dc.citation.issue10-
dc.citation.beginningpageP10020-
dc.citation.publicationnameJOURNAL OF INSTRUMENTATION-
dc.identifier.doi10.1088/1748-0221/15/10/P10020-
dc.contributor.localauthorCho, Gyuseong-
dc.contributor.nonIdAuthorKim, H.-
dc.contributor.nonIdAuthorPark, K.-
dc.contributor.nonIdAuthorHan, B.-
dc.contributor.nonIdAuthorChoi, K. D.-
dc.contributor.nonIdAuthorChang, H.-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorDosimetry concepts and apparatus-
dc.subject.keywordAuthorDetector control systems (detector and experiment monitoring and slow-control systems, architecture, hardware, algorithms, databases)-
dc.subject.keywordAuthorRadiation monitoring-
dc.subject.keywordPlusLUNG-CANCER-
dc.subject.keywordPlusRADON-
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0