Measurement of effective thermal conductivity of LaNi5 powder packed bed

Cited 14 time in webofscience Cited 6 time in scopus
  • Hit : 385
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKim, Dong-minko
dc.contributor.authorKim, Joongko
dc.contributor.authorLee, Jungchulko
dc.contributor.authorLee, Bong Jaeko
dc.date.accessioned2021-01-28T05:50:58Z-
dc.date.available2021-01-28T05:50:58Z-
dc.date.created2021-01-14-
dc.date.issued2021-02-
dc.identifier.citationINTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, v.165, pp.120735-
dc.identifier.issn0017-9310-
dc.identifier.urihttp://hdl.handle.net/10203/280001-
dc.description.abstractEffective thermal conductivity of LaNi5 powder packed bed was analyzed with a miniaturized guarded hot-plate (GHP) apparatus. Here, GHP was designed for precise measurement of effective thermal conductivity of metal-hydride powders even with small sample amounts (2.12 x 10(4) mm(3)). Dimensions of sample container and apparatus were determined through two-dimensional (2-D) steady-state heat conduction analysis. Calibration experiment and uncertainty analysis were conducted to validate the accuracy of the GHP. Based on the measurements of the residual thermal conductivity of the LaNi5 packed bed, effect of particle size on contact factor of LaNi5 packed bed was estimated. By applying the Yagi and Kunii (YK) model to the effective thermal conductivity of LaNi5 packed bed, effect of contact factor and gas thermal conductivity on characteristic length of gas film were newly analyzed. Factors of YK model were modified in present work and validated through comparison with experimental data from previous literature.-
dc.languageEnglish-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.titleMeasurement of effective thermal conductivity of LaNi5 powder packed bed-
dc.typeArticle-
dc.identifier.wosid000596070000034-
dc.identifier.scopusid2-s2.0-85096906029-
dc.type.rimsART-
dc.citation.volume165-
dc.citation.beginningpage120735-
dc.citation.publicationnameINTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER-
dc.identifier.doi10.1016/j.ijheatmasstransfer.2020.120735-
dc.contributor.localauthorLee, Jungchul-
dc.contributor.localauthorLee, Bong Jae-
dc.contributor.nonIdAuthorKim, Joong-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorMetal-hydride powder-
dc.subject.keywordAuthorEffective thermal conductivity-
dc.subject.keywordAuthorResidual thermal conductivity-
dc.subject.keywordAuthorGuarded hot-plate apparatus-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 14 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0