Pneumatic AFO Powered by a Miniature Custom Compressor for Drop Foot Correction

Cited 19 time in webofscience Cited 8 time in scopus
  • Hit : 296
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKim, Sangjoon Jonathanko
dc.contributor.authorNa, Youngjinko
dc.contributor.authorLee, Dong Yeonko
dc.contributor.authorChang, Handdeutko
dc.contributor.authorKim, Jungko
dc.date.accessioned2020-09-18T03:59:51Z-
dc.date.available2020-09-18T03:59:51Z-
dc.date.created2020-08-24-
dc.date.created2020-08-24-
dc.date.issued2020-08-
dc.identifier.citationIEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, v.28, no.8, pp.1781 - 1789-
dc.identifier.issn1534-4320-
dc.identifier.urihttp://hdl.handle.net/10203/276087-
dc.description.abstractFor active AFO applications, pneumatic remote transmission has advantages in minimizing the mass and complexity of the system due to the flexibility in placing pneumatic components and providing high back-drivability via simple valve control. However, pneumatic systems are generally tethered to large stationary air compressors, which greatly limit the practical daily usage. In this study, we implemented a wearable custom compressor that can be worn at the trunk of the body and can generate up to 1050 kPa of pressurized air to power an unilateral active AFO for dorsiflexion (DF) assistance of drop-foot patients. In order to minimize the size and weight of the custom compressor, the compression rate of the custom compressor was optimized to the rate of consumption required to power the active AFO. The finalized system can provide a maximum assistive torque of 9.8 Nm at a functional frequency of 1 Hz and the average resistive torque during free movement was 0.03 Nm. The system was tested for five hemiplegic drop-foot patients. The proposed system showed an average improvement of 12.3 degrees of ankle peak dorsiflexion angle during the mid to late swing phase.-
dc.languageEnglish-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.titlePneumatic AFO Powered by a Miniature Custom Compressor for Drop Foot Correction-
dc.typeArticle-
dc.identifier.wosid000556773500010-
dc.identifier.scopusid2-s2.0-85089206584-
dc.type.rimsART-
dc.citation.volume28-
dc.citation.issue8-
dc.citation.beginningpage1781-
dc.citation.endingpage1789-
dc.citation.publicationnameIEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING-
dc.identifier.doi10.1109/TNSRE.2020.3003860-
dc.contributor.localauthorKim, Jung-
dc.contributor.nonIdAuthorKim, Sangjoon Jonathan-
dc.contributor.nonIdAuthorNa, Youngjin-
dc.contributor.nonIdAuthorLee, Dong Yeon-
dc.contributor.nonIdAuthorChang, Handdeut-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorAssistive technology-
dc.subject.keywordAuthorcompressor-
dc.subject.keywordAuthorpneumatic system-
dc.subject.keywordAuthorrehabilitation robotics-
dc.subject.keywordPlusENERGETIC CHARACTERIZATION-
dc.subject.keywordPlusWALKING-
dc.subject.keywordPlusDESIGN-
dc.subject.keywordPlusORTHOSIS-
dc.subject.keywordPlusASSISTANCE-
dc.subject.keywordPlusMECHANISM-
dc.subject.keywordPlusGENERATOR-
dc.subject.keywordPlusPRESSURE-
dc.subject.keywordPlusACTUATOR-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 19 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0