We herein developed a simple personal glucose meter (PGM)-based method for terminal transferase (TdT) activity assay by utilizing the glucose oxidase (GOx)-mimicking activity of cerium oxide nanoparticles (CeO2 NPs). Using this strategy, the TdT activity was reliably determined down to 0.7 UmL(-1) with high selectivity against other non-specific enzymes.