Pulse pileup correction method for gamma-ray spectroscopy in high radiation fields

Cited 13 time in webofscience Cited 9 time in scopus
  • Hit : 503
  • Download : 513
DC FieldValueLanguage
dc.contributor.authorLee, Minjuko
dc.contributor.authorLee, Daeheeko
dc.contributor.authorKo, Eunbieko
dc.contributor.authorPark, Kyungjinko
dc.contributor.authorKim, Junhyukko
dc.contributor.authorKo, Kilyoungko
dc.contributor.authorSharma, Manishko
dc.contributor.authorCho, Gyuseongko
dc.date.accessioned2020-05-06T07:20:08Z-
dc.date.available2020-05-06T07:20:08Z-
dc.date.created2019-12-31-
dc.date.created2019-12-31-
dc.date.created2019-12-31-
dc.date.issued2020-05-
dc.identifier.citationNUCLEAR ENGINEERING AND TECHNOLOGY, v.52, no.5, pp.1029 - 1035-
dc.identifier.issn1738-5733-
dc.identifier.urihttp://hdl.handle.net/10203/274103-
dc.description.abstractThe detector suffers from pulse pileup by overlapping of the signals when it was used in high radiation fields. The pulse pileup deteriorates the energy spectrum and causes count losses due to random co-incidences, which might not resolve within the resolving time of the detection system. In this study, it is aimed to propose a new pulse pileup correction method. The proposed method is to correct the start point of the pileup pulse. The parameters are obtained from the fitted exponential curve using the peak point of the previous pulse and the start point of the pileup pulse. The amplitude at the corrected start point of the pileup pulse can be estimated by the peak time of the pileup pulse. The system is composed of a NaI (Tl) scintillation crystal, a photomultiplier tube, and an oscilloscope. A 61 mu Ci Cs-137 check-source was placed at a distance of 3 cm, 5 cm, and 10 cm, respectively. The gamma energy spectra for the radioisotope of Cs-137 were obtained to verify the proposed method. As a result, the correction of the pulse pileup through the proposed method shows a remarkable improvement of FWHM at 662 keV by 29, 39, and 7%, respectively.-
dc.languageEnglish-
dc.publisherKOREAN NUCLEAR SOC-
dc.titlePulse pileup correction method for gamma-ray spectroscopy in high radiation fields-
dc.typeArticle-
dc.identifier.wosid000526899400019-
dc.identifier.scopusid2-s2.0-85076978814-
dc.type.rimsART-
dc.citation.volume52-
dc.citation.issue5-
dc.citation.beginningpage1029-
dc.citation.endingpage1035-
dc.citation.publicationnameNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.identifier.doi10.1016/j.net.2019.12.003-
dc.identifier.kciidART002584331-
dc.contributor.localauthorCho, Gyuseong-
dc.contributor.nonIdAuthorLee, Daehee-
dc.contributor.nonIdAuthorKo, Eunbie-
dc.contributor.nonIdAuthorSharma, Manish-
dc.description.isOpenAccessY-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorGamma spectroscopy-
dc.subject.keywordAuthorScintillation detector-
dc.subject.keywordAuthorPulse pileup correction-
dc.subject.keywordAuthorScintillation pulse model-
dc.subject.keywordPlusREAL-TIME-
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 13 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0