Integrated calibration of multiview phase-measuring profilometry다중시점 위상측정기반 형상측정법을 위한 통합 캘리브레이션

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 370
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorKim, Min Hyuk-
dc.contributor.advisor김민혁-
dc.contributor.authorLee, Yeong Beum-
dc.date.accessioned2019-09-04T02:46:19Z-
dc.date.available2019-09-04T02:46:19Z-
dc.date.issued2018-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=734072&flag=dissertationen_US
dc.identifier.urihttp://hdl.handle.net/10203/267025-
dc.description학위논문(석사) - 한국과학기술원 : 전산학부, 2018.2,[iii, 30 p. :]-
dc.description.abstractPhase-measuring profilometry (PMP) measures per-pixel height information of a surface with high accuracy. Height information captured by a camera in PMP relies on its screen coordinates. Therefore, a PMP measurement from a view cannot be integrated directly to other measurements from different views due to the intrinsic difference of the screen coordinates. In order to integrate multiple PMP scans, an auxiliary calibration of each camera&amp-
dc.description.abstractamp-
dc.description.abstractrsquo-
dc.description.abstracts intrinsic and extrinsic properties is required, in addition to principal PMP calibration. This is cumbersome and often requires physical constraints in the system setup, and multiview PMP is consequently rarely practiced. In this work, we present a novel multiview PMP method that yields three-dimensional global coordinates directly so that three-dimensional measurements can be integrated easily. Our PMP calibration parameterizes intrinsic and extrinsic properties of the configuration of both a camera and a projector simultaneously. It also does not require any geometric constraints on the setup. In addition, we propose a novel calibration target that can remain static without requiring any mechanical operation while conducting multiview calibrations, whereas existing calibration methods require manually changing the target&#39-
dc.description.abstracts position and orientation. Our results validate the accuracy of measurements and demonstrate the advantages on our multiview PMP.-
dc.languageeng-
dc.publisher한국과학기술원-
dc.subject3D Reconstruction▼aSurface Reconstruction▼aCalibration-
dc.subject삼차원 복원▼a표면 복원▼a캘리브레이션-
dc.titleIntegrated calibration of multiview phase-measuring profilometry-
dc.title.alternative다중시점 위상측정기반 형상측정법을 위한 통합 캘리브레이션-
dc.typeThesis(Master)-
dc.identifier.CNRN325007-
dc.description.department한국과학기술원 :전산학부,-
dc.contributor.alternativeauthor이영범-
Appears in Collection
CS-Theses_Master(석사논문)
Files in This Item
There are no files associated with this item.