Three-Degrees-of-Freedom Passive Gravity Compensation Mechanism Applicable to Robotic Arm With Remote Center of Motion for Minimally Invasive Surgery

Cited 24 time in webofscience Cited 16 time in scopus
  • Hit : 697
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKim, Chang-Kyunko
dc.contributor.authorChung, Deok Gyoonko
dc.contributor.authorHwang, Minhoko
dc.contributor.authorCheon, Byungsikko
dc.contributor.authorKim, Hansoulko
dc.contributor.authorKim, Joonhwanko
dc.contributor.authorKwon, Dong-Sooko
dc.date.accessioned2019-08-21T09:20:04Z-
dc.date.available2019-08-21T09:20:04Z-
dc.date.created2019-08-19-
dc.date.created2019-08-19-
dc.date.created2019-08-19-
dc.date.issued2019-10-
dc.identifier.citationIEEE Robotics and Automation Letters, v.4, no.4, pp.3473 - 3480-
dc.identifier.issn2377-3766-
dc.identifier.urihttp://hdl.handle.net/10203/264370-
dc.description.abstractFor safety enhancement reasons, passive gravity compensation is widely applied in robotic systems used in minimally invasive surgery (MIS). MIS robotic systems have a remote center of motion(RCM) in which a surgical instrument conducts a fulcrum motion around a point of invasion. RCM mechanisms include three-degrees-of-freedom (3-DoF): roll, pitch, and translation. Existing studies to date have focused on multi-degrees-of-freedom gravity compensation mechanisms by installing springs and wires in a robot. However, a gravity compensation mechanism with 3-DoF that simultaneously uses all three-directional movements (roll, pitch, and translation) has not yet been researched. Here, we propose a novel gravity compensation mechanism applicable to a 3-DoF MIS robotic arm with an RCM mechanism. When a translational motion is exerted, the proposed gravity compensator can adjust the roll-pitch-directional compensating torque by utilizing a reduction gear box and wire cable. To verify the 3-DoF gravity compensation, a gravity-compensated robotic arm for MIS and customized torque sensors was manufactured and calibrated. The results showed that the proposed static balancing mechanism can compensate for the gravitational torque with respect to roll, pitch, and translation. The total torque error along the roll and pitch axis was less than 0.38 N.m. In particular, the torque variation due to the translational motion was less than 0.13 N.m.-
dc.languageEnglish-
dc.publisherInstitute of Electrical and Electronics Engineers Inc.-
dc.titleThree-Degrees-of-Freedom Passive Gravity Compensation Mechanism Applicable to Robotic Arm With Remote Center of Motion for Minimally Invasive Surgery-
dc.typeArticle-
dc.identifier.wosid000477983400009-
dc.identifier.scopusid2-s2.0-85069860578-
dc.type.rimsART-
dc.citation.volume4-
dc.citation.issue4-
dc.citation.beginningpage3473-
dc.citation.endingpage3480-
dc.citation.publicationnameIEEE Robotics and Automation Letters-
dc.identifier.doi10.1109/LRA.2019.2926953-
dc.contributor.localauthorKwon, Dong-Soo-
dc.contributor.nonIdAuthorKim, Chang-Kyun-
dc.contributor.nonIdAuthorChung, Deok Gyoon-
dc.contributor.nonIdAuthorKim, Hansoul-
dc.contributor.nonIdAuthorKim, Joonhwan-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorSurgical robotics: laparoscopy-
dc.subject.keywordAuthormechanism design-
dc.subject.keywordAuthorrobot safety-
dc.subject.keywordPlusDESIGN-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 24 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0