Efficient Data Extraction Method for Near-Infrared Spectroscopy (NIRS) Systems With High Spatial and Temporal Resolution

Cited 19 time in webofscience Cited 15 time in scopus
  • Hit : 261
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorChoi, Jong-Kwanko
dc.contributor.authorChoi, Min-Gyuko
dc.contributor.authorKim, Jae-Myoungko
dc.contributor.authorBae, Hyeon-Minko
dc.date.accessioned2019-04-15T15:32:20Z-
dc.date.available2019-04-15T15:32:20Z-
dc.date.created2013-05-23-
dc.date.issued2013-04-
dc.identifier.citationIEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, v.7, no.2, pp.169 - 177-
dc.identifier.issn1932-4545-
dc.identifier.urihttp://hdl.handle.net/10203/255058-
dc.description.abstractAn hardware-efficient method for the extraction of hemodynamic responses in near-infrared spectroscopy systems is proposed to increase the spatial and temporal resolution. The performance improvement is attributed to high signal-to-noise ratio receivers, a modulation scheme, and a multi-input-multi-output based data extraction algorithm. The proposed system shows more than twofold improvement in the figure of merit compared to conventional designs. Experimental results support the validity of the proposed system.-
dc.languageEnglish-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.subjectTISSUE OPTICAL-PROPERTIES-
dc.subjectBRAIN ACTIVATION-
dc.subjectADULT HEAD-
dc.subjectLIGHT-PROPAGATION-
dc.subjectFOCAL CHANGES-
dc.subjectMODEL-
dc.subjectREFLECTANCE-
dc.subjectOXYGENATION-
dc.subjectACCURACY-
dc.subjectHEMODYNAMICS-
dc.titleEfficient Data Extraction Method for Near-Infrared Spectroscopy (NIRS) Systems With High Spatial and Temporal Resolution-
dc.typeArticle-
dc.identifier.wosid000318797100008-
dc.identifier.scopusid2-s2.0-84877762032-
dc.type.rimsART-
dc.citation.volume7-
dc.citation.issue2-
dc.citation.beginningpage169-
dc.citation.endingpage177-
dc.citation.publicationnameIEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS-
dc.identifier.doi10.1109/TBCAS.2013.2255052-
dc.contributor.localauthorBae, Hyeon-Min-
dc.contributor.nonIdAuthorChoi, Jong-Kwan-
dc.contributor.nonIdAuthorChoi, Min-Gyu-
dc.contributor.nonIdAuthorKim, Jae-Myoung-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorCode division multiple access (CDMA)-
dc.subject.keywordAuthorhemodynamics-
dc.subject.keywordAuthormulti-input multi-output (MIMO)-
dc.subject.keywordAuthornear-infrared spectroscopy (NIRS)-
dc.subject.keywordAuthorspectroscopy-
dc.subject.keywordPlusTISSUE OPTICAL-PROPERTIES-
dc.subject.keywordPlusBRAIN ACTIVATION-
dc.subject.keywordPlusADULT HEAD-
dc.subject.keywordPlusLIGHT-PROPAGATION-
dc.subject.keywordPlusFOCAL CHANGES-
dc.subject.keywordPlusMODEL-
dc.subject.keywordPlusREFLECTANCE-
dc.subject.keywordPlusOXYGENATION-
dc.subject.keywordPlusACCURACY-
dc.subject.keywordPlusHEMODYNAMICS-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 19 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0