Free Convection Dominant Asymptotic Region in a Horizontal Tubular Reverse Osmosis

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 538
  • Download : 44
Axial invariance of production performance encountered in a horizontal tubular reverse osmosis has been analyzed by assuming that the free convection is the dominant transport mechanism. The governing equations, which had been deduced from dimensional analyses used in heat transfer problem with a large Prandtl number, have been solved approximately by the integral method. The numerical computations show that the system performance in terms of concentration polarization and wall permeation velocity, even if axially constant, is better at the top of the tube than at any other circumferential positions. The effects of system parameters such as feed concentration level, operating pressure and tube radius can also be explained from the results obtained.
Publisher
한국화학공학회
Issue Date
1979
Language
Korean
Citation

KOREAN CHEMICAL ENGINEERING RESEARCH(HWAHAK KONGHAK), v.17, no.3, pp.167 - 178

ISSN
0304-128X
URI
http://hdl.handle.net/10203/24199
Appears in Collection
CBE-Journal Papers(저널논문)
Files in This Item

qr_code

  • mendeley

    citeulike