Dynamic Simulation of the Water-steam System in Once-through Boilers - Sub-critical Power Boiler Case -관류보일러 물-증기 계통의 동적 시뮬레이션- 아임계 동력보일러 사례 -

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 1266
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKim, Sungilko
dc.contributor.authorChoi, Sangminko
dc.date.accessioned2017-09-25T06:04:16Z-
dc.date.available2017-09-25T06:04:16Z-
dc.date.created2017-09-18-
dc.date.created2017-09-18-
dc.date.created2017-09-18-
dc.date.issued2017-05-
dc.identifier.citationTRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, v.41, no.5, pp.353 - 363-
dc.identifier.issn1226-4881-
dc.identifier.urihttp://hdl.handle.net/10203/226158-
dc.description.abstractThe dynamics of a water-steam system in a once-through boiler was simulated based on the physics-based modeling approach, representing the system in response to large load change or scale disturbance simulations. The modeling considered the mass, energy conservation, and momentum equation in the water pipe and the focus was limited to the sub-critical pressure region. An evaporator tube modeling was validated against the reference data. A simplified boiler system consisting of economizer, evaporator, and superheater was constructed to match a 500 MW power boiler. The dynamic response of the system following a disturbance was discussed along with the quantitative response characteristics. The dynamic response of the boiler system was further evaluated by checking the case of an off-design point operation of the feedwater-to-fuel supply ratio. The results re-emphasized the significance of controlling the feedwater-to-fuel supply ratio and additional design requirements of the water-steam separator and spray attemperator.-
dc.languageKorean-
dc.publisherKOREAN SOC MECHANICAL ENGINEERS-
dc.titleDynamic Simulation of the Water-steam System in Once-through Boilers - Sub-critical Power Boiler Case --
dc.title.alternative관류보일러 물-증기 계통의 동적 시뮬레이션- 아임계 동력보일러 사례 --
dc.typeArticle-
dc.identifier.scopusid2-s2.0-85027714406-
dc.type.rimsART-
dc.citation.volume41-
dc.citation.issue5-
dc.citation.beginningpage353-
dc.citation.endingpage363-
dc.citation.publicationnameTRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B-
dc.identifier.doi10.3795/KSME-B.2017.41.5.353-
dc.identifier.kciidART002222384-
dc.contributor.localauthorChoi, Sangmin-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorOnce-through Boiler-
dc.subject.keywordAuthorWater-Steam Dynamic Flow-
dc.subject.keywordAuthorSubcritical Pressure-
dc.subject.keywordPlusSUPERCRITICAL CFB BOILER-
dc.subject.keywordPlusWALL-
dc.subject.keywordPlusMODEL-