5kW급 SOFC 시스템의 연료 개질기를 위한 2-유체 노즐과 3-유체 노즐의 검토Examination of 2-Fluid Nozzle and 3-Fluid Nozzle for Fuel Reformer of 5 kW SOFC System

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 471
  • Download : 1612
In the present study, the 2-fluid nozzle and 3-fluid nozzle to atomize the diesel and water with air for the fuel reformer of SOFC system were experimentally examined. In the 2-fluid nozzle, the diesel and water were alternately atomized due to bislug flow pattern, and it implies that the mixing of both liquids strongly affects the atomization pattern. On the other hand, in the 3-fluid nozzle, the diesel and water were atomized simultaneously due to the separated injection channels without mixing problem. Therefore, compared to the 2-fluid nozzle, the 3-fluid nozzle is suitable for the stable operation of the fuel reformer. In case of the 3-fluid nozzle, Type A where the air was supplied through the central channel was the most efficient.
Publisher
한국액체미립화학회
Issue Date
2008
Keywords

Fuel Reformer; 2-Fluid Nozzle; 3-Fluid Nozzle

Citation

한국액체미립화학회지, Vol.13, No.1, pp.16-21

URI
http://hdl.handle.net/10203/22516
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
48.pdf(4.49 MB)Download