Self-Gated Cardiac Cine Imaging Using Phase Information

Cited 5 time in webofscience Cited 0 time in scopus
  • Hit : 535
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorSeo, Hyunseokko
dc.contributor.authorKim, Dongchanko
dc.contributor.authorOh, Changheunko
dc.contributor.authorPark, HyunWookko
dc.date.accessioned2017-05-08T08:48:18Z-
dc.date.available2017-05-08T08:48:18Z-
dc.date.created2017-04-18-
dc.date.created2017-04-18-
dc.date.issued2017-03-
dc.identifier.citationMAGNETIC RESONANCE IN MEDICINE, v.77, no.3, pp.1216 - 1222-
dc.identifier.issn0740-3194-
dc.identifier.urihttp://hdl.handle.net/10203/223501-
dc.description.abstractPurpose: To obtain multiphase cardiac cine images with high resolution, a novel self-gating method for both cardiac and respiratory motions is proposed. Methods: The proposed method uses the phase of projection data obtained from a separate axial slice to measure cardiac and respiratory motion, after the acquisition of every k-space line in the image plane. Cardiac motion is estimated from the phase of the projection data passing through the aorta, which is amplified by superior-inferior directional bipolar gradients, whereas respiratory motion is estimated from the phase of the left-right directional projection data of the abdomen. To verify the proposed self-gating method, a simulation and in vivo steady state free precession cardiac imaging were performed. Results: The proposed method provides high resolution multiphase cardiac cine images. Using the proposed self-gating method, the phase variation of the projection data offers information about cardiac and respiratory motions that is equivalent to external gating devices. Conclusion: The proposed method can capture time-resolved cardiac and respiratory motion from the phase information of the projection data. Because the projection data is obtained from a separate gating slice, the self-gating signals are not affected by imaging planes. (C) 2016 International Society for Magnetic Resonance in Medicine-
dc.languageEnglish-
dc.publisherWILEY-BLACKWELL-
dc.subjectHEART CORONARY MRA-
dc.subjectWHOLE-HEART-
dc.subjectRESPIRATORY MOTION-
dc.subjectGATING TECHNIQUE-
dc.subjectRADIAL SSFP-
dc.subjectRECONSTRUCTION-
dc.subjectANGIOGRAPHY-
dc.subjectARTERIES-
dc.subjectSENSE-
dc.titleSelf-Gated Cardiac Cine Imaging Using Phase Information-
dc.typeArticle-
dc.identifier.wosid000397407800031-
dc.identifier.scopusid2-s2.0-84961837221-
dc.type.rimsART-
dc.citation.volume77-
dc.citation.issue3-
dc.citation.beginningpage1216-
dc.citation.endingpage1222-
dc.citation.publicationnameMAGNETIC RESONANCE IN MEDICINE-
dc.identifier.doi10.1002/mrm.26204-
dc.contributor.localauthorPark, HyunWook-
dc.contributor.nonIdAuthorKim, Dongchan-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorcardiac cine-
dc.subject.keywordAuthorcardiac magnetic resonance imaging (CMR)-
dc.subject.keywordAuthorfree-breathing-
dc.subject.keywordAuthorself-gating-
dc.subject.keywordAuthorsteady state free precession (SSFP)-
dc.subject.keywordPlusHEART CORONARY MRA-
dc.subject.keywordPlusWHOLE-HEART-
dc.subject.keywordPlusRESPIRATORY MOTION-
dc.subject.keywordPlusGATING TECHNIQUE-
dc.subject.keywordPlusRADIAL SSFP-
dc.subject.keywordPlusRECONSTRUCTION-
dc.subject.keywordPlusANGIOGRAPHY-
dc.subject.keywordPlusARTERIES-
dc.subject.keywordPlusSENSE-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 5 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0