(A) pneumatic haptic interface for simulation of catheter카테터 시뮬레이션을 위한 공압 구동 방식의 햅틱 인터페이스

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 630
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorLee, Doo Yong-
dc.contributor.advisor이두용-
dc.contributor.authorHwang, Jihye-
dc.contributor.author황지혜-
dc.date.accessioned2017-03-29T02:30:28Z-
dc.date.available2017-03-29T02:30:28Z-
dc.date.issued2016-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=663280&flag=dissertationen_US
dc.identifier.urihttp://hdl.handle.net/10203/221275-
dc.description학위논문(석사) - 한국과학기술원 : 기계공학과, 2016.8 ,[v, 78 p. :]-
dc.description.abstractCatheter is a thin tube inserted into a human body for treatments in various medical procedures because of accurate access to the disease area, small amount of blood loss and patients’ fast recovery. A catheter is manipulated by a doctor watching images acquired through a camera at the tip of the endoscope or CT (computerized tomography). Medical simulations have been studied to provide novice doctors with training of catheter manipulation. Catheter haptic interface is essential in the simulation, which provides crucial information and cues. A catheter haptic interface is proposed in this research. The designed haptic interface provides two degrees-of freedom of translational and rotation motions by the pneumatic module made of silicon rubber. The pneumatic module has cylindrical shape with a hollow space inside. The space inside of the module can be filled with air supplied by the syringe pump, and grasp the catheter traveling through the module. The syringe pump is designed with a ball screw and a motor. The catheter position is detected by rubber-coated rotary encoder and passive roller. Experiment is conducted to identify the force and torque capacity of the haptic module. The measured force and torque have a linear relation with the pressure. The force range is 3.61N, and the error between the measured data and calibrated equation is 8.02%. The torque range is 3.494mNm, and the error between the measured data and calibrated equation is 10.79%. Assessment of the haptic module is conducted by a medical surgeon. The proposed haptic interface is expected to provide necessary haptic sensations during simulation of catheter operation.-
dc.languageeng-
dc.publisher한국과학기술원-
dc.subjecthaptic interface-
dc.subjectcatheter simulation-
dc.subjectmedical simulation-
dc.subjectgastrointestinal endoscopy-
dc.subjectpercutaneous coronary intervention-
dc.subject햅틱 인터페이스-
dc.subject카테터 시뮬레이션-
dc.subject의료 시뮬레이션-
dc.subject소화기 내시경-
dc.subject관상동맥 중재술-
dc.title(A) pneumatic haptic interface for simulation of catheter-
dc.title.alternative카테터 시뮬레이션을 위한 공압 구동 방식의 햅틱 인터페이스-
dc.typeThesis(Master)-
dc.identifier.CNRN325007-
dc.description.department한국과학기술원 :기계공학과,-
Appears in Collection
ME-Theses_Master(석사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0