Position Estimation Using Linear Hall Sensors for Permanent Magnet Linear Motor Systems

Cited 65 time in webofscience Cited 0 time in scopus
  • Hit : 440
  • Download : 0
This paper proposes a new scaleless position estimation method. From the industrial perspective, the Hall sensor has several advantages: tiny size, light weight, extremely lowcost, and insensitivity to environmental contamination and external disturbance. Compared to the square wave Hall sensor, the linear Hall sensor provides more detailed information along the position. However, for combining more than two linear Hall sensors, the sensor offset, the difference in scale, and the unwanted phase shift between them and the harmonics would decrease the validity and reliability of sensor measurement. The fast Fourier transform and the fixed point iteration method are applied to compensate for those issues without any low-pass filter or additional signal conditioning. The effectiveness of the proposed scheme is verified through a prototype permanent magnet linear synchronous motor system.
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Issue Date
2016-12
Language
English
Article Type
Article
Citation

IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, v.63, no.12, pp.7644 - 7652

ISSN
0278-0046
DOI
10.1109/TIE.2016.2591899
URI
http://hdl.handle.net/10203/218293
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 65 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0