A low-profile three-dimensional neural probe array using a silicon lead transfer structure

Cited 15 time in webofscience Cited 14 time in scopus
  • Hit : 322
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorCheng, Ming-Yuanko
dc.contributor.authorJe, Minkyuko
dc.contributor.authorTan, Kwan Lingko
dc.contributor.authorTan, Ee Limko
dc.contributor.authorLim, Ruiqiko
dc.contributor.authorYao, Leiko
dc.contributor.authorLi, Pengko
dc.contributor.authorPark, Woo-Taeko
dc.contributor.authorPhua, Eric Jian Rongko
dc.contributor.authorGan, Chee Lipko
dc.contributor.authorYu, Aibinko
dc.date.accessioned2016-06-29T02:09:38Z-
dc.date.available2016-06-29T02:09:38Z-
dc.date.created2016-04-08-
dc.date.created2016-04-08-
dc.date.created2016-04-08-
dc.date.created2016-04-08-
dc.date.issued2013-09-
dc.identifier.citationJOURNAL OF MICROMECHANICS AND MICROENGINEERING, v.23, no.9-
dc.identifier.issn0960-1317-
dc.identifier.urihttp://hdl.handle.net/10203/208526-
dc.description.abstractThis paper presents a microassembly method for low-profile three-dimensional probe arrays for neural prosthesis and neuroscience applications. A silicon (Si) lead transfer structure, Si interposer, is employed to form electrical connections between two orthogonal planes-the two dimensional probes and the dummy application-specific integrated circuit (ASIC) chip. In order to hold the probe array and facilitate the alignment of probes during assembly, a Si platform is designed to have through-substrate slots for the insertion of probes and cavities for holding the Si interposers. The electrical interconnections between the probes and the dummy ASIC chip are formed by solder reflow, resulting in greatly improved throughput in the proposed assembly method. Moreover, since the backbone of the probe can be embedded inside the cavity of the Si platform, the profile of the probe array above the cortical surface can be controlled within 750 mu m. This low-profile allows the probe array not to touch the skull after it is implanted on the brain. The impedance of the assembled probe is also measured and discussed.-
dc.languageEnglish-
dc.publisherIOP PUBLISHING LTD-
dc.subjectDEVICES-
dc.titleA low-profile three-dimensional neural probe array using a silicon lead transfer structure-
dc.typeArticle-
dc.identifier.wosid000323814100014-
dc.identifier.scopusid2-s2.0-84884844502-
dc.type.rimsART-
dc.citation.volume23-
dc.citation.issue9-
dc.citation.publicationnameJOURNAL OF MICROMECHANICS AND MICROENGINEERING-
dc.identifier.doi10.1088/0960-1317/23/9/095013-
dc.contributor.localauthorJe, Minkyu-
dc.contributor.nonIdAuthorCheng, Ming-Yuan-
dc.contributor.nonIdAuthorTan, Kwan Ling-
dc.contributor.nonIdAuthorTan, Ee Lim-
dc.contributor.nonIdAuthorLim, Ruiqi-
dc.contributor.nonIdAuthorYao, Lei-
dc.contributor.nonIdAuthorLi, Peng-
dc.contributor.nonIdAuthorPark, Woo-Tae-
dc.contributor.nonIdAuthorPhua, Eric Jian Rong-
dc.contributor.nonIdAuthorGan, Chee Lip-
dc.contributor.nonIdAuthorYu, Aibin-
dc.type.journalArticleArticle-
dc.subject.keywordPlusDEVICES-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 15 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0