dc.description.abstractTo obtain 3D MR angiography having high contrast between vessel and stationary background tissue, a novel technique called sliding time of flight (TOF) is proposed. The proposed method relies on the property that flow-related enhancement (FRE) is maximized at the blood-entering slice in an imaging slab. For the proposed sliding TOF, a sliding stack-of-stars sampling and a dynamic MR image reconstruction algorithm were developed. To verify the performance of the proposed method, in-vivo study was performed and the results were compared with multiple overlapping thin 3D slab acquisition (MOTSA) and sliding interleaved ky (SLINKY). In MOTSA and SLINKY, the variation of FRE resulted in severe venetian blind (MOTSA) or ghost (SLINKY) artifacts, while the vessel-contrast increased as the flip angle of RF pulses increased. On the other hand, the proposed method could provide high-contrast angiograms with reduced FRE-related artifacts. The sliding TOF can provide 3D angiography without image artifacts even if high flip angle RF pulses with thick slab excitation are used. Although remains of subsampling artifacts can be present in the reconstructed images, they can be reduced by MIP operation and resolved further by regularization techniques.eng
dc.languageeng-
dc.publisher한국과학기술원-
dc.subjectstack-of-stars trajectory-
dc.subjectsliding slab-
dc.subjectTOF-
dc.subject혈관조영술-
dc.subjectMOTSA-
dc.subject이동식 샘플링-
dc.subject동적영상복원법-
dc.titleHigh contrast MR angiography using sliding sampling scheme and dynamic reconstruction method-
dc.title.alternative이동식 영상획득방법과 동적 영상복원법을 이용한 고 대비 혈관조영술-
dc.typeThesis(Ph.D)-
dc.identifier.CNRN591833/325007 -
dc.description.department한국과학기술원 : 전기및전자공학과, -
dc.identifier.uid020105422-
dc.contributor.localauthorPark, Hyun-Wook-
dc.contributor.localauthor박현욱-
Appears in Collection
EE-Theses_Ph.D.(박사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0