A High-Sensitivity and Low-Walk Error LADAR Receiver for Military Application

Cited 71 time in webofscience Cited 63 time in scopus
  • Hit : 363
  • Download : 0
An integrated receiver with high sensitivity and low walk error for a military purpose pulsed time-of-flight (TOF) LADAR system is proposed. The proposed receiver adopts a dual-gain capacitive-feedback TIA (C-TIA) instead of widely used resistive-feedback TIA (R-TIA) to increase the sensitivity. In addition, a new walk-error improvement circuit based on a constant-delay detection method is proposed. Implemented in 0.35 mu m CMOS technology, the receiver achieves an input-referred noise current of 1.36 pA/root Hz with bandwidth of 140 MHz and minimum detectable signal (MDS) of 10 nW with a 5 ns pulse at SNR = 3.3, maximum walk-error of 2.8 ns, and a dynamic range of 1:12,000 over the operating temperature range of -40 degrees C to +85 degrees C
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Issue Date
2014-10
Language
English
Article Type
Article
Keywords

FLIGHT LASER RANGEFINDER; CHANNEL; RADAR; ACCURACY

Citation

IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, v.61, no.10, pp.3007 - 3015

ISSN
1549-8328
DOI
10.1109/TCSI.2014.2327282
URI