Cyclic Loading Test for Beam-Column Connections with 600 MPa (87 ksi) Beam Flexural Reinforcing Bars

Cited 44 time in webofscience Cited 0 time in scopus
  • Hit : 946
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorHwang, Hyeon-Jongko
dc.contributor.authorPark, Hong-Gunko
dc.contributor.authorChoi, Won-Seokko
dc.contributor.authorChung, Lanko
dc.contributor.authorKim, Jin-Keunko
dc.date.accessioned2014-09-01T08:38:14Z-
dc.date.available2014-09-01T08:38:14Z-
dc.date.created2014-07-29-
dc.date.created2014-07-29-
dc.date.issued2014-07-
dc.identifier.citationACI STRUCTURAL JOURNAL, v.111, no.4, pp.913 - 924-
dc.identifier.issn0889-3241-
dc.identifier.urihttp://hdl.handle.net/10203/189629-
dc.description.abstractAn experimental study was performed to evaluate the seismic performance of beam-column connections using Grade 600 MPa (87.0 ksi) bars for beam flexural reinforcement. Four full-scale interior connections and three exterior connections were tested under cyclic lateral loading. The specimens were designed according to the special seismic provisions in ACI 318-11. The column depth-beam reinforcing bar diameter ratios h(c)/d(b) were 20.5 to 25.0. The structural performance of the specimens with 600 MPa (87.0 ksi) D22 (diameter = 22 mm [0.87 in.]) and D25 (diameter = 25 mm [0.98 in.]) bars were directly compared with that of the specimen with 400 MPa (58.0 ksi) D25 bars. In the case of the interior connections, the load-carrying capacity and maximum deformation were close to those of the specimen with 400 MPa (58.0 ksi) bars. On the other hand, the energy dissipation capacity of the specimens with 600 MPa (87.0 ksi) bars decreased by a maximum of 25% due to the increased bond-slip at the joints. In the case of the exterior connections, significant bond-slip occurred at the beam bottom bars due to insufficient development length, which decreased the deformation capacity and energy dissipation capacity of the specimens.-
dc.languageEnglish-
dc.publisherAMER CONCRETE INST-
dc.titleCyclic Loading Test for Beam-Column Connections with 600 MPa (87 ksi) Beam Flexural Reinforcing Bars-
dc.typeArticle-
dc.identifier.wosid000337925800018-
dc.identifier.scopusid2-s2.0-84903955352-
dc.type.rimsART-
dc.citation.volume111-
dc.citation.issue4-
dc.citation.beginningpage913-
dc.citation.endingpage924-
dc.citation.publicationnameACI STRUCTURAL JOURNAL-
dc.contributor.localauthorKim, Jin-Keun-
dc.contributor.nonIdAuthorHwang, Hyeon-Jong-
dc.contributor.nonIdAuthorPark, Hong-Gun-
dc.contributor.nonIdAuthorChoi, Won-Seok-
dc.contributor.nonIdAuthorChung, Lan-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorhigh-strength reinforcement-
dc.subject.keywordAuthorreinforced beam-column joint-
dc.subject.keywordAuthorreinforcing bar-
dc.subject.keywordAuthorseismic performance test-
Appears in Collection
CE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 44 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley