Liquid film thickness inside the high pressure swirl injectors: Real scale measurement and evaluation of analytical equations

Cited 28 time in webofscience Cited 0 time in scopus
  • Hit : 431
  • Download : 0
Liquid film thickness inside two swirl injectors for direct injection (DI) gasoline engines was measured at different injection pressure conditions ranging from 2.0 to 7.0 MPa and then previous analytical and empirical equations were examined from the experimental results. Based on the evaluation, a new equation for the liquid film thickness inside the swirl injectors was introduced. A direct photography using two real scale transparent nozzles and a pulsed light source was employed to measure the liquid film thickness inside the swirl injectors. The error in the liquid film thickness measurement, generated from different refractive indices among transparent nozzle, fuel and air, was estimated and corrected based on the geometric optics. Two injectors which have different nozzle diameter and nozzle length were applied to introduce a more general empirical equation for the liquid film thickness inside the pressure swirl injectors. The results showed that the liquid film thickness remains constant at the injection pressures for direct injection gasoline engines while the ratio of nozzle length to nozzle diameter (L/D) shows significant effect on the liquid film thickness. The previously introduced analytical and empirical equations for relatively low injection pressure swirl injectors overestimated the effect of injection pressure at the operating range of high pressure swirl injectors and, in addition, the effect of L/D ratio and swirler geometry was rarely considered. A new empirical equation was suggested based on the experimental results by taking into account the effects of fuel properties, nozzle diameter, nozzle length and swirler geometry. (C) 2009 Elsevier Inc. All rights reserved.
Publisher
ELSEVIER SCIENCE INC
Issue Date
2010-02
Language
English
Article Type
Article
Keywords

AIR-CORE; NOZZLE; ATOMIZER; FLOW

Citation

EXPERIMENTAL THERMAL AND FLUID SCIENCE, v.34, no.2, pp.113 - 121

ISSN
0894-1777
DOI
10.1016/j.expthermflusci.2009.09.007
URI
http://hdl.handle.net/10203/100540
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 28 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0