초전도 관내연선도체 접합부에서의 전류 불균일에 대한 수치적 분석Numerical analysis about current non-uniformity in superconducting CICC (cable-in-conduit conductor) joint

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 446
  • Download : 0
This paper presents transport current non-uniformity in a joint for superconducting multistage cable-in-conduit conductor (CICC) and relaxation in the CICC. The joint is considered to have a current loop linked to an external magnetic field so that it becomes an emf voltage source. It is numerically analyzed using an electrical transmission line model. The inductive current in a resistive joint is compared to that of a non-resistive joint when the ramping field is applied vertically to the joints. Regarding the parameter values of the model. a full scale $Nb_3Sn$ CICC and a strand-to-strand (STS) joint for the toroidal field magnet of the KSTAR (Korea Superconducting Tokamak Advanced Research) device are referenced to. It is found that the resistive joint prevents the current from rising too much and enhances decaying the current when the ramping stops. The flattop current is found to be proportional to the ramp rate of the field (dB/dt). The relaxation length, which is defined as the length within which the maximum induced current falls by 1/e. is found to saturate within 0.27m.
Publisher
한국초전도.저온공학회
Issue Date
2007-09
Language
Korean
Citation

한국초전도.저온공학회논문지, v.9, no.3, pp.41 - 45

ISSN
1229-3008
URI
http://hdl.handle.net/10203/92014
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0