dc.description.abstract | This paper summarizes an engineering approach taken for 10 commercial MSW incinerators to formulate a basis for PCDD/F emission reduction schemes and to interpret the measurement results before and after the plant modifications of moderate scale. Control strategy of PCDD/F emission from the operating incinerators can be established on the basis of the interpretation of reliable measurements as well as understanding of the formation/destruction processes. The fate of PCDD/F is known to be influenced by the flue gas subprocesses: the initial formation/oxidation in the combustion chamber, reformation through synthesis, removal by adsorption, and catalytic destruction. A simplified model is proposed for PCDD/F level at various stages of the flue gas, basically integrating the reaction kinetic rates at the corresponding state. Since the kinetic rate is dependent on temperature, time-temperature history of the flue gas is considered as the important input data. Using the plant design and operating conditions, this global prediction model calculates the PCDD/F level not only at the stack but also at the process midstream. The model predictions are discussed along with measurement results from the different design of incinerator plants. | - |
dc.description.sponsorship | Energy and Environment Research Center of KAIST, Institute of Environmental and Energy Technology of POSTECH. | en |
dc.language | English | - |
dc.language.iso | en_US | en |
dc.publisher | AMER CHEMICAL SOC | - |
dc.subject | DE-NOVO-SYNTHESIS | - |
dc.subject | FLY-ASH | - |
dc.subject | FLUE-GAS | - |
dc.subject | CHLOROPHENOL REACTIONS | - |
dc.subject | REFUSE INCINERATION | - |
dc.subject | MSW INCINERATORS | - |
dc.subject | FABRIC FILTER | - |
dc.subject | DIOXINS | - |
dc.subject | CARBON | - |
dc.subject | COMBUSTION | - |
dc.title | Evaluation of polychlorinated dibenzo-p-dioxin/dibenzofuran (PCDD/F) emission in municipal solid waste incinerators | - |
dc.type | Article | - |
dc.identifier.wosid | 000081811200044 | - |
dc.identifier.scopusid | 2-s2.0-0033178849 | - |
dc.type.rims | ART | - |
dc.citation.volume | 33 | - |
dc.citation.issue | 15 | - |
dc.citation.beginningpage | 2657 | - |
dc.citation.endingpage | 2666 | - |
dc.citation.publicationname | ENVIRONMENTAL SCIENCE TECHNOLOGY | - |
dc.identifier.doi | 10.1021/es980932r | - |
dc.embargo.liftdate | 9999-12-31 | - |
dc.embargo.terms | 9999-12-31 | - |
dc.contributor.localauthor | Choi, Sangmin | - |
dc.contributor.nonIdAuthor | Shin, DH | - |
dc.contributor.nonIdAuthor | Oh, JE | - |
dc.contributor.nonIdAuthor | Chang, YS | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordPlus | DE-NOVO-SYNTHESIS | - |
dc.subject.keywordPlus | FLY-ASH | - |
dc.subject.keywordPlus | FLUE-GAS | - |
dc.subject.keywordPlus | CHLOROPHENOL REACTIONS | - |
dc.subject.keywordPlus | REFUSE INCINERATION | - |
dc.subject.keywordPlus | MSW INCINERATORS | - |
dc.subject.keywordPlus | FABRIC FILTER | - |
dc.subject.keywordPlus | DIOXINS | - |
dc.subject.keywordPlus | CARBON | - |
dc.subject.keywordPlus | COMBUSTION | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.