Construction of low-noise electrochemical quartz-crystal microbalance and study in redox reaction on electrode surface저 잡음 수정 진동 저울의 제작과 전극표면에서의 산화/환원 반응에 관한 연구

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 554
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorKwak, Ju-Hyoun-
dc.contributor.advisor곽주현-
dc.contributor.authorKim, Jeong-Ho-
dc.contributor.author김정호-
dc.date.accessioned2011-12-13T05:01:45Z-
dc.date.available2011-12-13T05:01:45Z-
dc.date.issued1998-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=135266&flag=dissertation-
dc.identifier.urihttp://hdl.handle.net/10203/32791-
dc.description학위논문(석사) - 한국과학기술원 : 화학과, 1998.2, [ iv, 55 p. ]-
dc.description.abstractTo study adsorption processes on electrode surface,low-noise electrochemical quartz-crystal microbalance (EQCM), of which oscillator is op-amp relaxation type, was made through a lot of trial and errors. The adsorption process is fundamental and plays central role in electrochemistry. But the quantitative investigation had not almost carried out until middle 1980‘s. With the advent of EQCM at that time, active studies have been carried out. As much as fundamental, the adsorption process between electrode and electrolyte is difficult to study. So, very low noisy EQCM and pure chemicals are necessary. In this thesis, underpotential deposition of lead, of which chemistry had been known well, was investigated. Rigorous Ar-bubbling control is essential because the irreducible redox reaction of the dissolved oxygen is not negligible. The catalytic effect of lead on reduction of the dissolved oxygen was verified. A strange reduction peak during oxidative scanning was also appeared, maybe caused by reducible reduction of the dissolved oxygen in the quasiequilibrium state. Also the slight upper shift of current-potential curve or mismatching between current curve in cyclic voltammogram and that estimated from EQCM data in the range of bulk deposition might be attributable to the same reason. For more severe identifying, more of less qualitative technique such as impedance analysis is required.eng
dc.languageeng-
dc.publisher한국과학기술원-
dc.subjectFrequency-
dc.subjectCyclic voltammogram-
dc.subjectIrreducibility-
dc.subjectDissolved oxygen-
dc.subjectOxidation-
dc.subjectReduction-
dc.subjectEQCM-
dc.subjectQCM-
dc.subjectPotential-
dc.subject전류-
dc.subject퍼텐셜-
dc.subject진동수-
dc.subject비가역성-
dc.subject용존산소-
dc.subject산화-
dc.subjectCurrent-
dc.subject수정진동저울-
dc.subject환원-
dc.titleConstruction of low-noise electrochemical quartz-crystal microbalance and study in redox reaction on electrode surface-
dc.title.alternative저 잡음 수정 진동 저울의 제작과 전극표면에서의 산화/환원 반응에 관한 연구-
dc.typeThesis(Master)-
dc.identifier.CNRN135266/325007-
dc.description.department한국과학기술원 : 화학과, -
dc.identifier.uid000963148-
dc.contributor.localauthorKwak, Ju-Hyoun-
dc.contributor.localauthor곽주현-
Appears in Collection
CH-Theses_Master(석사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0