Empirical investigation of occupant-centric thermal comfort in hotel guestrooms

Cited 1 time in webofscience Cited 0 time in scopus
  • Hit : 139
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorLee, Junsooko
dc.contributor.authorCHA, SEUNG HYUNko
dc.contributor.authorHong, Taehoonko
dc.contributor.authorKoo, Choongwanko
dc.date.accessioned2023-11-20T05:00:09Z-
dc.date.available2023-11-20T05:00:09Z-
dc.date.created2023-11-20-
dc.date.created2023-11-20-
dc.date.issued2024-01-
dc.identifier.citationRENEWABLE & SUSTAINABLE ENERGY REVIEWS, v.189, no.part: B-
dc.identifier.issn1364-0321-
dc.identifier.urihttp://hdl.handle.net/10203/314836-
dc.description.abstractGiven the importance of occupant satisfaction with thermal comfort in hotel accommodations, previous studies have assessed thermal comfort using either local or global standards. In a hotel catering to diverse guests, a single standard may constrain the formulation of an optimal strategy for improving occupant satisfaction. To address this challenge, this study empirically investigates occupant-centric thermal comfort in hotel guestrooms located in a hot and humid climatic region. To this end, a living-lab-based case study was conducted on a hotel guestroom in Hong Kong, wherein two types of thermal comfort improvement strategies were devised from both local and global perspectives. First, to improve thermal comfort in line with the local standard, it was determined that an ancillary fan coil unit (FCU) energy consumption of 6.0 kW h (approximately 34 % of the existing energy consumption) was required. Second, to improve thermal comfort in line with the global standard, an ancillary FCU energy consumption of 9.4 kW h (approximately 53 % of the existing energy consumption) was necessary. Consequently, in a hot and humid climatic region, the distribution of thermal comfort may vary depending on the type of guest (e.g., domestic or foreign), and ancillary cooling energy expenditure may be incurred to enhance a guest's thermal comfort. The proposed approach is expected to contribute to the creation of occupant-tailored thermal comfort by considering an individual's thermal acclimation to a specific climatic region from both local and global perspectives.-
dc.languageEnglish-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.titleEmpirical investigation of occupant-centric thermal comfort in hotel guestrooms-
dc.typeArticle-
dc.identifier.wosid001111815200001-
dc.identifier.scopusid2-s2.0-85177788948-
dc.type.rimsART-
dc.citation.volume189-
dc.citation.issuepart: B-
dc.citation.publicationnameRENEWABLE & SUSTAINABLE ENERGY REVIEWS-
dc.identifier.doi10.1016/j.rser.2023.114046-
dc.contributor.localauthorCHA, SEUNG HYUN-
dc.contributor.nonIdAuthorLee, Junsoo-
dc.contributor.nonIdAuthorHong, Taehoon-
dc.contributor.nonIdAuthorKoo, Choongwan-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorThermal comfort-
dc.subject.keywordAuthorHotel guestrooms-
dc.subject.keywordAuthorThermal acclimatization-
dc.subject.keywordAuthorA hot and humid climate-
dc.subject.keywordAuthorLocal and global standards-
dc.subject.keywordAuthorAncillary cooling energy expenditure-
dc.subject.keywordPlusINDOOR ENVIRONMENTAL-QUALITY-
dc.subject.keywordPlusENERGY PERFORMANCE-
dc.subject.keywordPlusBUILDINGS-
dc.subject.keywordPlusSTRATEGIES-
dc.subject.keywordPlusOPERATION-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusMODEL-
Appears in Collection
GCT-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 1 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0