dc.contributor.author | Chan, Wei Xuan | ko |
dc.contributor.author | Yoon, Yong-Jin | ko |
dc.contributor.author | Shin, Choongsoo S. | ko |
dc.contributor.author | Kim, Namkeun | ko |
dc.date.accessioned | 2019-06-17T07:30:07Z | - |
dc.date.available | 2019-06-17T07:30:07Z | - |
dc.date.created | 2019-06-12 | - |
dc.date.created | 2019-06-12 | - |
dc.date.issued | 2019-06 | - |
dc.identifier.citation | IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, v.66, no.6, pp.1609 - 1617 | - |
dc.identifier.issn | 0018-9294 | - |
dc.identifier.uri | http://hdl.handle.net/10203/262636 | - |
dc.description.abstract | Residual hearing loss in cochlear implant users is investigated using the mechanical-human-cochlear model. Hearing loss due to stiffening of the round window increases significantly as input frequencies decrease from 3 kHz to 1 kHz but remains constant at lower frequencies, whereas loss due to the presence of an electrode insert becomes significantly higher at lower frequencies (< 1 kHz). The latter also shifts the characteristic frequency map toward the basal end of the cochlea. In the region away from the end of the electrode insert, cochlear function recovers, but the user still suffers from hearing loss caused by round window stiffening. | - |
dc.language | English | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.title | Mechanical Effects of Cochlear Implant on Acoustic Hearing | - |
dc.type | Article | - |
dc.identifier.wosid | 000468432000013 | - |
dc.identifier.scopusid | 2-s2.0-85055058323 | - |
dc.type.rims | ART | - |
dc.citation.volume | 66 | - |
dc.citation.issue | 6 | - |
dc.citation.beginningpage | 1609 | - |
dc.citation.endingpage | 1617 | - |
dc.citation.publicationname | IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING | - |
dc.identifier.doi | 10.1109/TBME.2018.2876402 | - |
dc.contributor.localauthor | Yoon, Yong-Jin | - |
dc.contributor.nonIdAuthor | Chan, Wei Xuan | - |
dc.contributor.nonIdAuthor | Shin, Choongsoo S. | - |
dc.contributor.nonIdAuthor | Kim, Namkeun | - |
dc.description.isOpenAccess | N | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | Speech recognition | - |
dc.subject.keywordAuthor | human cochlea | - |
dc.subject.keywordAuthor | cochlear implant | - |
dc.subject.keywordAuthor | residual hearing | - |
dc.subject.keywordAuthor | basilar membrane | - |
dc.subject.keywordPlus | BASILAR-MEMBRANE | - |
dc.subject.keywordPlus | INTRACOCHLEAR PRESSURE | - |
dc.subject.keywordPlus | ELECTRODE INSERTION | - |
dc.subject.keywordPlus | MODEL | - |
dc.subject.keywordPlus | AMPLIFICATION | - |
dc.subject.keywordPlus | DEPTH | - |
dc.subject.keywordPlus | MORPHOLOGY | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.