Highly sensitive Mach-Zehnder interferometer biosensor based on silicon nitride slot waveguide

Cited 176 time in webofscience Cited 0 time in scopus
  • Hit : 188
  • Download : 0
We demonstrate a highly sensitive label-free Mach-Zehnder interferometer (MZI) biosensor based on silicon nitride slot waveguide. Unlike the conventional MZI sensors, the sensing arm of the sensor consists of a slot waveguide while the reference arm consists of a strip waveguide. Thanks to the slot waveguide's property to provide high optical intensity in a subwavelength-size low refractive index region (slot region), which allows high light-analyte interaction, higher sensitivity can be obtained as compared to conventional waveguides using the slot waveguide as sensing region. The bulk refractive index sensitivity of the slot waveguide MZI sensor was found to be 1864 pi/RIU (refractive index unit) with 7 mm long slot waveguide sensing arm, which shows higher sensitivity compared to the conventional MZI device based on silicon nitride. The biosensing capability of the developed slot waveguide MZI was investigated using biotin-streptavidin binding as a model system. The sensitivity of the system was demonstrated down to 18.9 fM or 1 pg/ml of streptavidin solution and to the best of our knowledge, it is the best reported experimental value for the limit of detection of a MZI sensor. Furthermore, we investigated the specific detection and quantification of the methylation of DAPIC (Death-associated protein kinase) gene, which is a widely used biomarker for human cancers. We have shown that methylation sequences of DAPIC gene of various methylation densities (100%, 50%, and 0% of methylation sites) can be quantified and discriminated even at a concentration as low as 1 fmol/mu l or 1 nM. (C) 2013 Elsevier B.V. All rights reserved.
Publisher
ELSEVIER SCIENCE SA
Issue Date
2013-11
Language
English
Article Type
Article
Keywords

PHOTONIC MICRORING RESONATORS; LABEL-FREE; MULTIPLEXED DETECTION; ON-INSULATOR; DAP-KINASE; SENSOR; CANCER; ARRAYS; HYPERMETHYLATION; RECOGNITION

Citation

SENSORS AND ACTUATORS B-CHEMICAL, v.188, pp.681 - 688

ISSN
0925-4005
DOI
10.1016/j.snb.2013.07.053
URI
http://hdl.handle.net/10203/245984
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 176 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0