Multi-Classier-Based Automatic Polyp Detection in Endoscopic Images

Cited 4 time in webofscience Cited 0 time in scopus
  • Hit : 324
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorCho, Yeong-Junko
dc.contributor.authorBae,Seung-Hwanko
dc.contributor.authorYoon, Kuk-Jinko
dc.date.accessioned2018-04-24T04:28:36Z-
dc.date.available2018-04-24T04:28:36Z-
dc.date.created2018-03-29-
dc.date.created2018-03-29-
dc.date.created2018-03-29-
dc.date.created2018-03-29-
dc.date.issued2016-12-
dc.identifier.citationJournal of Medical and Biological Engineering, v.36, no.6, pp.871 - 882-
dc.identifier.issn1609-0985-
dc.identifier.urihttp://hdl.handle.net/10203/241268-
dc.description.abstractAutomatic polyp detection in endoscopy (or colonoscopy) images is challenging because the types of polyp and their appearances are diverse, and the colors and textures of polyps are quite similar to those of normal tissues in many cases. It is thus often very difficult to distinguish polyps from normal tissues using conventional methodology. To effectively resolve these challenges, we propose a framework based on multi-classifier learning and a contour intensity difference (CID) measure. To detect polyps of diverse appearances, we first classify polyps into K types according to their shape via unsupervised learning. We then train K classifiers to detect the K types of polyp. This multi-classifier learning improves the polyp detection rate. However, false positives also increase because colon structures look similar to polyps. To reduce false positives while preserving the high detection rate, we propose a CID measure. Experimental results using public and our own datasets show that the proposed methods are promising for detecting polyps with diverse appearances.-
dc.languageEnglish-
dc.publisherSPRINGER HEIDELBERG-
dc.titleMulti-Classier-Based Automatic Polyp Detection in Endoscopic Images-
dc.typeArticle-
dc.identifier.wosid000392085100012-
dc.identifier.scopusid2-s2.0-85008425552-
dc.type.rimsART-
dc.citation.volume36-
dc.citation.issue6-
dc.citation.beginningpage871-
dc.citation.endingpage882-
dc.citation.publicationnameJournal of Medical and Biological Engineering-
dc.identifier.doi10.1007/s40846-016-0190-4-
dc.contributor.localauthorYoon, Kuk-Jin-
dc.contributor.nonIdAuthorCho, Yeong-Jun-
dc.contributor.nonIdAuthorBae,Seung-Hwan-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorMedical imaging-
dc.subject.keywordAuthorMedical engineering-
dc.subject.keywordAuthorAutomatic polyp detection-
dc.subject.keywordAuthorMulti-classifier learning-
dc.subject.keywordAuthorContour intensity difference measure-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 4 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0